Humidity is the presence of water vapor in the air. In view of its effect on human health and the physical qualities of materials, humidity must be measured and controlled. Humidity measurement is imperative in a variety of fields including health care, environmental monitoring, automobiles, air-conditioning, civil engineering, agriculture, semiconductors, pharmaceuticals, textiles, paper and processing industries. This book provides an overview of humidity and the types and applications of humidity sensors. This book will be helpful for students, researchers and general readers.
Chalcone derivatives have been synthesized by reaction of 1-(2,5-dimethyl-furan-3-yl)-ethanone with corresponding active aldehyde in ethanolic NaOH in microwave oven. The structure of these compounds was established by elemental analysis, IR, 1H-NMR, 13C-NMR, and EI-MS spectral analysis. The anti-bacterial activity of these compounds was first tested in vitro by the disc diffusion assay against two Gram-positive and two Gram-negative bacteria, and then the minimum inhibitory concentration (MIC) was determined with the reference of standard drug Chloramphenicol. The results showed that pyrazol containing chalcone (compound 8) inhibited both types of bacteria (Gram-positive and Gram-negative) better than chloramphenicol.
A reliable xanthine (XNT) chemical sensor was fabricated using a facile wet-chemical method (by co-precipitation) to prepare ZnO/Al<sub>2</sub>O<sub>3</sub>/Cr<sub>2</sub>O<sub>3</sub> nanoparticles (NPs) in an alkaline medium at low temperature. Powder X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDS), Fourier transform infrared spectroscopy (FTIR) and ultraviolet-visible spectroscopy (UV-vis) were implemented for detailed characterization of the NPs. To fabricate the working electrode as a XNT chemical sensor probe, a glassy carbon electrode (GCE) with a 0.0316 cm<sup>2</sup> surface area was coated with an ethanolic slurry of the prepared ZnO/Al<sub>2</sub>O<sub>3</sub>/Cr<sub>2</sub>O<sub>3</sub> NPs to make a thin layer and used to analyse XNT in a phosphate buffer system. To evaluate the analytical performances of the XNT chemical sensor, the calibration curve of XNT was plotted as the relationship of current <i>versus</i> the concentration of XNT. The plotted calibration curve was found to be linear over the LDR (linear dynamic range) of 0.05 nM to 5.0 μM. The assembled XNT electrochemical sensor exhibited the highest sensitivity (70.8861 μA μM<sup>-1</sup> cm<sup>-2</sup>), the lowest detection limit (1.34 ± 0.07 pM), good reproducibility performance with high accuracy and long-term stability with standard results under ambient conditions. This is a simple route to selectively detect XNT with wet-chemically prepared co-doped ZnO/Al<sub>2</sub>O<sub>3</sub>/Cr<sub>2</sub>O<sub>3</sub> nanomaterials using a reliable electrochemical method at a large scale for safety within healthcare fields.
A Cu nanoparticle-embedded N-doped carbon nanowire array on copper foam (Cu–N–C NA/CF) shows high catalytic activity, needing an overpotential of 314 mV to drive a geometrical current density of 20 mA cm<sup>−2</sup> in 1.0 M KOH.