Article
2006
en
Authors
SN
Sriram Narasimhan
Satish Nagarajaiah
Rice University
Abstract
1 min read
A new control algorithm is developed for reducing the response of smart base isolated buildings with variable friction semiactive control systems in near-fault earthquakes. The central idea of the control algorithm is to design a H∞ controller for the structural system and use this controller to determine the optimum control force in the semiactive device. The H∞ controller is designed using appropriate input and output weighting filters that have been developed for optimal performance in reducing near-fault earthquake responses. A novel semiactive variable friction device is also developed and with the H∞ controller shown to be effective in achieving response reductions in smart base isolated buildings in near-fault earthquakes. The new variable friction device developed consists of four friction elements and four restoring spring elements arranged in a rhombus configuration with each arm consisting of a friction–stiffness pair. The level of friction force can be adjusted by varying the angle of the arms of the device leading to smooth variation of friction force in the device. Experimental results are presented to verify the proposed analytical model of the device. The H∞ algorithm is implemented analytically on a five storey smart base isolated building with linear elastomeric isolation bearings and variable friction system located at the isolation level. The H∞ controller along with the weighting filters leads to the smooth variation of friction force, thus eliminating the disadvantages associated with rapid switching. Several recent near-fault earthquakes are considered in this study. The robustness of the H∞ controller is shown by considering a stiffness uncertainty of ±10%. Copyright © 2006 John Wiley & Sons, Ltd.
Discussion
(0)
Sign in
to like and join the discussion.
No comments yet. Be the first to comment.
Related publications
Article
2006
Seismic control of smart base isolated buildings with new semiactive variable damper
Satish Nagarajaiah
,
Sriram Narasimhan
Article
2005
Seismic response control of smart sliding isolated buildings using variable stiffness systems: an experimental and numerical study
Satish Nagarajaiah
,
Sanjay Sahasrabudhe
Article
2005
Effectiveness of Variable Stiffness Systems in Base-isolated Bridges Subjected to Near-fault Earthquakes: An Experimental and Analytical Study
Sanjay Sahasrabudhe
,
Satish Nagarajaiah
Article
2005
Experimental Study of Sliding Base-Isolated Buildings with Magnetorheological Dampers in Near-Fault Earthquakes
Sanjay Sahasrabudhe
,
Satish Nagarajaiah
Article
2005
Smart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systems
Satish Nagarajaiah
,
Sriram Narasimhan
Discussion(0)