1 min read
Sample controllers for a three-dimensional smart base-isolated building benchmark problem with linear and frictional isolation system are presented in this paper. A Kalman filter is used to estimate the states based on absolute acceleration measurements. Input filters are used to better inform the controller of the spectral content of the earthquake excitations. A reduced order control-oriented model of the benchmark structure with a linear isolation system is developed. A H2/linear quadratic Gaussian controller is presented for the active case; additionally, a clipped optimal controller is presented for the semiactive case. A preliminary 'skyhook' semiactive controller is also presented for the benchmark problem. Magnetorheological fluid dampers are used for control in the semiactive case and ideal actuators are used for control in the active case. The focus of this phase I study is on the linear isolation system only. Computed results for the passive, semiactive, and active cases are presented. Detailed comparisons of benchmark performance indices for base-isolated structures with a nominal linear isolation system, with and without control, for a set of strong near-field earthquakes are presented. The modeling and sample control designs demonstrated in this paper can be used to form the basis for studying a wide variety of active and semiactive control strategies—to be developed by the participants in the benchmark study—for linear base-isolated buildings. Copyright © 2005 John Wiley & Sons, Ltd.
Discussion
(0)
Sign in
to like and join the discussion.
No comments yet. Be the first to comment.
Related publications
Article
2008
Smart base-isolated benchmark building part IV: Phase II sample controllers for nonlinear isolation systems
Sriram Narasimhan
,
Satish Nagarajaiah
,
E. A. Johnson
Article
2009
Benchmark structural control problem for a seismically excited highway bridge-Part III: Phase II Sample controller for the fully base-isolated case
Satish Nagarajaiah
,
Sriram Narasimhan
,
Anil K. Agrawal
,
Ping Tan
Article
2005
Smart base-isolated benchmark building. Part I: problem definition
Sriram Narasimhan
,
Satish Nagarajaiah
,
E. A. Johnson
,
Henri P. Gavin
Article
2006
Semiactive Lyapunov Controller for Phase II Seismic Isolated Highway Bridge Benchmark
Satish Nagarajaiah
,
Sriram Narasimhan
,
Anil K. Agrawal
,
Ping Tan
Article
2008
Structural control benchmark problem: Phase II-Nonlinear smart base-isolated building subjected to near-fault earthquakes
Satish Nagarajaiah
,
Sriram Narasimhan
,
E. A. Johnson
Discussion(0)
No comments yet. Be the first to comment.