Angiographic Geometric Changes of the Lumen Arterial Wall After Bioresorbable Vascular Scaffolds and Metallic Platform Stents at 1-Year Follow-Up
КАРДИОЛОГИЯ УЗБЕКИСТАНА 4(7): 789-799
Article 2011 English
Authors
JG
Josep Gómez‐Lara
SB
Salvatore Brugaletta
VF
Vasim Farooq
Abstract
2 min read
Objectives
The aim of this study was to compare the angiographic changes in coronary geometry of the bioresorbable vascular scaffolds (BVS) and metallic platform stent (MPS) between baseline and follow-up.
Background
Coronary geometry changes after stenting might result in wall shear stress changes and adverse events. The BVS have better conformability, compared with MPS, but still modify artery geometry. It is uncertain whether the BVS resorption can restore the coronary anatomical configuration at midterm follow-up.
Methods
All patients of the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions) and SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions) trials treated with a single 3.0 × 18 mm device and imaged at baseline and 6- to 12-month follow-up were eligible. Coronary geometry changes were assessed with quantitative angiography as changes in curvature and angulation. Curvature and angulation changes between systole and diastole were investigated to assess hinging movements of the coronary artery.
Results
One hundred sixty-one patients (86 BVS, and 75 MPS) were included. Baseline angiographic characteristics were similar. From post-implantation to follow-up, curvature increased 8.4% (p < 0.01) with BVS and decreased 1.9% (p = 0.54) with MPS; p = 0.01. Angulation increased 11.3% with BVS (p < 0.01) and 3.8% with MPS (p = 0.01); p < 0.01. From pre-implantation to follow-up, BVS decreased 3.4% the artery curvature (p = 0.05) and 3.9% the artery angulation (p = 0.16), whereas MPS presented with 26.1% decrease in curvature (p < 0.01) and 26.9% decrease in angulation (p < 0.01), being larger with MPS (p < 0.01, both). Hinging movements in curvature from pre-implantation to follow-up decreased 19.7% with BVS and 39.0% with MPS (p = 0.27) and decreased 3.9% with BVS and 26.9% with MPS in angulation (p < 0.01).
Conclusions
At midterm follow-up, the BVS tended to restore the coronary configuration and the systo-diastolic movements to those seen before implantation. The coronary geometry remained similar to that seen at after implantation with MPS. (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00856856)
Josep Gómez‐Lara, Héctor M. García‐García, Yoshinobu Onuma, Scot Garg, Evelyn Regar, Bernard De Bruyne, Stefan Windecker, Dougal McClean, Leif Thuesen, Dariusz Dudek, Jacques Koolen, Robert Whitbourn, Pieter C. Smits, Bernard Chevalier, Cécile Dorange, Susan Veldhof, Marie-Angèle Morel, Ton de Vries, John A. Ormiston, Patrick W. Serruys
Takashi Muramatsu, Yoshinobu Onuma, Robert‐Jan van Geuns, Bernard Chevalier, Tejas Patel, Ashok Seth, Roberto Diletti, Héctor M. García‐García, Cécile Dorange, Susan Veldhof, Wai-Fung Cheong, Yukio Ozaki, Robert Whitbourn, Antonio L. Bartorelli, Gregg W. Stone, Alexandre Abizaid, Patrick W. Serruys
Patrick W. Serruys, Yuki Katagiri, Yohei Sotomi, Yaping Zeng, Bernard Chevalier, René J. van der Schaaf, Andreas Baumbach, Pieter C. Smits, Nicolas M. Van Mieghem, Antonio L. Bartorelli, Paul Barragan, Anthony Gershlick, Ran Kornowski, Carlos Macaya, John A. Ormiston, Jonathan Hill, Iréne Lang, Mohaned Egred, Jean Fajadet, Maciej Lesiak, Stephan Windecker, Robert A. Byrne, Lorenz Räber, Robert‐Jan van Geuns,
Adriano Caixeta, Alexandra J. Lansky, Patrick W. Serruys, James Hermiller, Peter Ruygrok, Yoshinobu Onuma, Paul Gordon, Manejeh Yaqub, Karine Miquel‐Hébert, Susan Veldhof, Poornima Sood, Xiaolu Su, Lalitha Jonnavithula, Krishnankutty Sudhir, Gregg W. Stone
Yao‐Jun Zhang, Christos V. Bourantas, Takashi Muramatsu, Javaid Iqbal, Vasim Farooq, Roberto Diletti, Carlos M. Campos, Yoshinobu Onuma, Héctor M. García‐García, Patrick W. Serruys
Discussion(0)
No comments yet. Be the first to comment.