Analysis of the ZVS two‐switch forward converter with synchronous current doubler rectifier — Bor Ren Lin (2007) | RDL Network
Back
Cite
Save
Save for later
Share
Home
Publications
Analysis of the ZVS two‐switch forward converter with synchronous current doubler rectifier
Shared by
Bor Ren Lin
Analysis of the ZVS two‐switch forward converter with synchronous current doubler rectifier
Article
2007
en
Authors
Bor Ren Lin
JW
Jin‐Fa Wan
Abstract
1 min read
Abstract A soft switching two‐switch forward converter is presented to achieve zero voltage switching (ZVS) turn‐on of switching devices. In the adopted converter, a buck‐boost type of active clamp is connected in parallel with the primary winding of transformer. The energy stored in the transformer leakage inductance and magnetizing inductance can be recovered so that the peak voltage stress of switching devices is limited. The resonance between the transient interval of two main and auxiliary switches is used to achieve ZVS turn‐on of all switches. The current doubler synchronous rectifier is used in the secondary side of transformer for reducing the root mean square value of output inductor current, transformer secondary winding current and output voltage ripple by cancelling the current ripple of two output inductors. First, the circuit configuration and the principles of operation are analyzed in detail. The steady‐state analysis and design consideration are also presented. Finally, experimental results with a laboratory prototype based on a 380 V input and 12 V/30 A output were provided to verify the effectiveness of the proposed converter. Copyright © 2007 John Wiley & Sons, Ltd.
Discussion
(0)
Sign in
to like and join the discussion.
No comments yet. Be the first to comment.
Related publications
Article
2007
Analysis of the Two-Switch Forward Converter with Synchronous Current Doubler Rectifier
Bor Ren Lin
,
Jin‐Fa Wan
,
Chien-Lan Huang
,
Huann‐Keng Chiang
Article
2007
Soft Switching Interleaved Forward Converter with Current Doubler Rectifier
Bor Ren Lin
,
Chun‐Chi Chen
,
Jin‐Fa Wan
,
Chunsheng Yang
Article
2007
Analysis and Implementation of an Active Clamp Two-Switch Converter with Current Doubler Rectifie
Bor Ren Lin
,
Jin‐Fa Wan
,
F.-Y. Hsieh
Article
2008
Interleaved ZVS Converter With Ripple-Current Cancellation
Bor Ren Lin
,
Chien-Lan Huang
Article
2007
Analysis and implementation of a soft switching interleaved forward converter with current doubler rectifier
Bor Ren Lin
,
Huann‐Keng Chiang
Discussion(0)
No comments yet. Be the first to comment.