A Screen-Printed Electrode Modified With Graphene/Co3O4 Nanocomposite for Electrochemical Detection of Tramadol — Mohammad Reza Aflatoonian (2020) | RDL Network
A Screen-Printed Electrode Modified With Graphene/Co3O4 Nanocomposite for Electrochemical Detection of Tramadol
Article 2020 en
Authors
MA
Mohammad Reza Aflatoonian
ST
Somayeh Tajik
BA
Behnaz Aflatoonian
Abstract
1 min read
In this paper, graphene (Gr)/Co<sub>3</sub>O<sub>4</sub> nanocomposite was synthesized and utilized for the development of a novel electrochemical sensor to detect tramadol. Tramadol determination was examined by linear sweep voltammetry, differential pulse voltammetry, cyclic voltammetry, and chronoamperometry on Gr/Co<sub>3</sub>O<sub>4</sub> nanocomposite-modified screen-printed electrode (Gr/Co<sub>3</sub>O<sub>4</sub>/SPE) in phosphate-buffered saline (PBS). Under the optimized condition, the detection limit of tramadol is 0.03 μM (S/N = 3) in the linear ranges of 0.1-500.0 μM. Furthermore, Gr/Co<sub>3</sub>O<sub>4</sub>/SPE was satisfactorily utilized to detect tramadol in tramadol tablet and urine specimens.
Peyman Mohamadzadeh Jahani, Sayed Zia Mohammadi, Ali Khodabakhshzadeh, Mehdi Shahedi Asl, Ho Won Jang, Mohammadreza Shokouhimehr, Kaiqiang Zhang, Quyet Van Le, Wanxi Peng