3-Dimensional Optical Coherence Tomography Assessment of Jailed Side Branches by Bioresorbable Vascular Scaffolds
КАРДИОЛОГИЯ УЗБЕКИСТАНА 3(8): 836-844
Article 2010 English
Authors
TO
Takayuki Okamura
YO
Yoshinobu Onuma
HG
Héctor M. García‐García
Abstract
1 min read
Objectives
The purpose of this study is to assess jailing of side branches (SB) by the everolimus-eluting, bioresorbable vascular scaffold (BVS) with 3-dimensional (3D) optical coherence tomography (OCT) reconstruction.
Background
Because BVS struts at the SB orifice are suspected of being bioresorbed and/or forming a neointimal bridge, OCT has been used to evaluate the struts in detail at that particular site. Our understanding of the 3D relationship of the strut and the SB orifice is limited by the use of 2-dimensional OCT images. Fourier-domain OCT enables reliable 3D reconstruction of coronary vessels.
Methods
The ABSORB Cohort B (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions) trial is a multicenter single-arm trial to assess the safety and performance of the BVS. Fourier-domain OCT pullbacks (C7-XR system, LightLab Imaging Inc., Westford, Massachusetts) are obtained at pullback speed of 20 mm/s and 3D renderings are performed. The orifices of the SB are assessed visually. The area of SB orifice and the number of strut-free compartments delineated by the BVS struts are evaluated.
Results
Fifty-one OCT pullbacks were acquired: 33 pullbacks were imaged with Fourier-domain OCT and 27 treated segments had 46 side branches. Three-dimensional assessment was feasible in 87% (40 of 46) of pullbacks. The mean area of the SB orifice was 1.16 ± 1.02 mm2. The mean number of strut-free compartments was 2.0 ± 1.1. The classification of the overhanging struts is proposed.
Conclusions
This study demonstrates that 3D OCT reconstruction is feasible to evaluate the orifices of SB jailed with BVS. (ABSORB Clinical Investigation, Cohort B; NCT00856856)
Yoshinobu Onuma, Maik J. Grundeken, Shimpei Nakatani, Taku Asano, Yohei Sotomi, Nicolas Foin, Jaryl Ng, Takayuki Okamura, Joanna J. Wykrzykowska, Robbert J. de Winter, Robert‐Jan van Geuns, Jacques Koolen, Evald Høj Christiansen, Robert Whitbourn, Dougal McClean, Pieter C. Smits, Stephan Windecker, John A. Ormiston, Patrick W. Serruys
Vasim Farooq, Patrick W. Serruys, Jung Ho Heo, Bill D. Gogas, Yoshinobu Onuma, Laura Perkins, Roberto Diletti, Maria Radu, Lorenz Räber, Christos V. Bourantas, Yao‐Jun Zhang, Eric van Remortel, Ravindra Pawar, Richard Rapoza, Jennifer Powers, Heleen M.M. van Beusekom, Héctor M. García‐García, Renu Virmani
Josep Gómez‐Lara, Salvatore Brugaletta, Roberto Diletti, Scot Garg, Y. Onuma, Bill D. Gogas, Robert J. Van Geuns, Cécile Dorange, Susan Veldhof, Richard Rapoza, Robert Whitbourn, Stephan Windecker, Héctor M. García‐García, Evelyn Regar, Patrick W. Serruys
Yohei Sotomi, Hiroki Tateishi, Pannipa Suwannasom, Jouke Dijkstra, Jeroen Eggermont, Shengnan Liu, Erhan Tenekecioğlu, Yaping Zheng, Mohammad Abdelghani, Rafael Cavalcante, Robbert J. de Winter, Joanna J. Wykrzykowska, Yoshinobu Onuma, Patrick W. Serruys, Takeshi Kimura
The International Journal of Cardiovascular Imaging
Erhan Tenekecioğlu, Ryo Torii, Yuki Katagiri, Ply Chichareon, Taku Asano, Yosuke Miyazaki, Kuniaki Takahashi, Rodrigo Modolo, Rasha Al‐Lamee, Kadem Al-Lameé, Carlos Colet, Johan H. C. Reiber, Kerem Pekkan, Robert van Geuns, Christos V. Bourantas, Yoshinobu Onuma, Patrick W. Serruys
The International Journal of Cardiovascular Imaging
Discussion(0)
No comments yet. Be the first to comment.