6,963 publications from this institution
AIMS: This study examined the six-month angiographic results of direct coronary stenting, and compared the nine-month safety, efficacy and cost of this strategy versus stenting after balloon predilatation. METHODS: In phase I of VELVET, 122 patients (mean age = 62.3 - 10.1 years, 77% male, 11% with diabetes) with angina pectoris or myocardial ischemia resulting from a single de novo 51% to 95% coronary stenosis underwent direct stenting. The endpoints of phase I included angiographic findings and rates of major adverse cardiac events up to six months of follow-up. In phase II, 401 patients (mean age = 61.3 - 10.8 years, 79% male, 16% with diabetes) with angina pectoris or documented myocardial ischemia resulting from single or multiple, de novo or restenotic, coronary lesions were randomized between direct stenting and stenting after predilatation. The immediate angiographic results, and clinical outcomes and costs associated with the two treatment strategies up to nine months of follow-up were compared. RESULTS: In phase I the mean diameter stenosis immediately before and after the procedure, and at six months was 61.7 - 9.4%, 13.5 - 6.3%, and 33.6 - 16.2%, respectively. The six-month binary restenosis rate was 11%. The overall rate of major adverse cardiac events, including two non-cardiac deaths, was 9.8%. In phase II, the success rates of the intended delivery strategies were 87.9% and 97.9% for direct stenting and predilatation, respectively (p < 0.001), while the procedural success rates were similar (93.9% vs 96.5%). Over a follow-up period of nine months, major adverse cardiac events rates were 12.0% and 10.9% in patients randomized to direct stenting and predilatation, respectively (non-significant). Analyses of the costs incurred up to nine months in each treatment group revealed a mean saving of e362 per patient in favor of the direct stenting strategy (non-significant). CONCLUSIONS: Compared with a strategy of stenting preceded by balloon dilatation, direct stenting was associated with an equivalent procedural success rate, equivalent clinical results up to nine months of follow-up, and a reduction in procedural and in-hospital costs (p < 0.0001 and p < 0.001, respectively), that was no longer significant after nine months.
This year marks the 350th anniversary of the death of Ben Jonson – who, but for the happenstance of Shakespeare, would certainly have been Britain's national playwright, but whose achievement has in fact been overshadowed not only by the genius of his sometime colleague, but by the quite different styles and theatrical assumptions of their respective work. The dramatist Peter Barnes, who acknowledges a debt to Jonson in his own writing, is also a leading director of the playwright's work, with productions of Eastward Ho, The Alchemist, Bartholomew Fair , and The Devil is an Ass already to his credit, and, among other productions planned for this anniversary year, one of TheMagnetic Lady for BBC Radio, in apt juxtaposition to the projected RSC revival of The New Inn . Here, Peter Barnes contributes a personal celebration of the playwright's distinctive and defiantly unquenchable work.
No abstract is provided for this article.
Breath tests cover the fraction of nitric oxide in expired gas (FeNO), volatile organic compounds (VOCs), variables in exhaled breath condensate (EBC) and other measurements. For EBC and for FeNO, official recommendations for standardised procedures are more than 10 years old and there is none for exhaled VOCs and particles. The aim of this document is to provide technical standards and recommendations for sample collection and analytic approaches and to highlight future research priorities in the field. For EBC and FeNO, new developments and advances in technology have been evaluated in the current document. This report is not intended to provide clinical guidance on disease diagnosis and management.Clinicians and researchers with expertise in exhaled biomarkers were invited to participate. Published studies regarding methodology of breath tests were selected, discussed and evaluated in a consensus-based manner by the Task Force members.Recommendations for standardisation of sampling, analysing and reporting of data and suggestions for research to cover gaps in the evidence have been created and summarised.Application of breath biomarker measurement in a standardised manner will provide comparable results, thereby facilitating the potential use of these biomarkers in clinical practice.
A new study adds to the mounting evidence implicating T cells as an important component of the inflammation in chronic obstructive pulmonary disease.
No abstract is provided for this article.