Beta adrenoceptor subtypes in canine tracheal smooth muscle have been investigated by radioligand binding and by physiological responses to beta agonists and sympathetic nerve stimulation in vitro. Specific binding of [3H]dihydroalprenolol to tracheal smooth muscle membranes was of high affinity (Kd = 1.0 +/- 0.08 nM), as in peripheral lung membranes from the same animals, but the concentration of binding sites (95.6 +/- 4.7 fmol/mg of protein) was much lower than in lung (532 +/- 48 fmol/mg of protein). Binding was stereoselective and agonists competed with the rank order of potency isoproterenol greater than epinephrine greater than norepinephrine, signifying a preponderance of beta-2 receptors. Using selective beta antagonists, we determined the ratio of beta-1/beta-2 receptors in tracheal smooth muscle membranes to be 1:4. The relaxation response of tracheal smooth muscle strips to exogenous beta agonists was mediated by beta-2 receptors, with a very small contribution from beta-1 receptors. However, the relaxation response to electrical field stimulation of sympathetic nerves was mediated predominantly by beta-1 receptors. Our results suggest that most beta receptors in dog tracheal smooth muscle are of the beta-2 subtype and mediate responses to circulating catecholamines, but there is a small concentration of beta-1 receptors which mediate the response to neurally released norepinephrine.
This paper describes numerical modeling of the structural response of stainless steel hollow sections. The aim of the investigation was to develop a consistent approach to the modeling of stainless steel structures. The developed finite element models are more sophisticated than any other reported attempts to model stainless steel structural behavior, with general expressions defined for material stress–strain behavior, enhanced strength corner properties, initial geometric imperfection modes, and amplitudes (local and global), and residual stresses. The general expressions define a consistent means of describing the key input parameters. A compound (two-stage) Ramberg–Osgood model is developed to describe stainless steel material stress–strain behavior in tension and compression. For the prediction of enhanced strength corner properties, a simple, though accurate model is proposed. Characterization of local plate imperfection amplitudes is described whereby a model originally devised for hot-rolled carbon steel cross sections was recalibrated and applied to stainless steel cross sections. Numerical prediction of the key performance measures from tests is achieved with a high degree of accuracy: On average, ultimate load was predicted to within 3% and with a low standard deviation; deformation at ultimate load was within 6%, but exhibited a higher standard deviation; and the general form of the load–deformation response and the failure modes were similar.
Early stent thrombosis occurs in about 1% to 1.5% of patients with drug-eluting stents, very similar to the rate with bare-metal stents. Late stent thrombosis is more of a concern with drug-eluting stents, with an incidence of at least 0.35%. I would urge caution if you feel you have to stop antiplatelet therapy in patients with drug-eluting stents. While neointima formation peaks at 6 months and then may actually regress with bare-metal stents, it continues to grow with drug-eluting stents--although this process appears to plateau by 4 years with sirolimus. With the others, we have to wait and see. We still don't know the best drug-eluting stent. Trials are under way to compare stents with surgery, and the future brings the arrival of a number of exciting new devices and approaches that are now entering clinical trials.