A study into the mechanical behaviour and design of steel equal-leg cruciform section members subjected to axial compression is presented. Experimental data from the literature are used to validate shell finite element models developed within the commercial package ABAQUS for their load-deformation and ultimate behaviour. A numerical parametric study then considers cruciform section columns with a wide range of slenderness ratios and various common boundary conditions. The mechanical response and load-carrying capacity are shown to be dependent not only on the column slenderness but also on the torsional to flexural elastic buckling load ratio. Finally, a recently established design approach for steel angle section columns is extended to include cruciform section members, and verified against the available results. It is found through reliability analysis based on the EN 1990 procedure that the new proposal also offers substantially improved accuracy and consistency in strength predictions compared to the existing codified design rules for cruciform section columns; a recommended partial safety factor of 1.0 is determined.
The advent of intracoronary stents has greatly increased the safety and applicability of percutaneous coronary interventions. One of the drawbacks of drug-eluting stents (DES) is the increased risk of late and very late stent thrombosis (ST). It was anticipated that the risks of ST after DES implantation would be solved with the advent of fully biodegradable scaffolds, which offer the possibility of transient scaffolding of the vessel to prevent acute vessel closure and recoil while also transiently eluting an antiproliferative drug to counteract constrictive remodelling and excessive neointimal hyperplasia. In spite of the enthusiasm for the concept of bioresorbable scaffolds, current clinical data on the Absorb bioresorbable vascular scaffold (BVS) have generated concerns about scaffold thrombosis (ScT) in both the early and late phases. However, the causes of ScT in both the early and late phases have yet to be fully elucidated. This article seeks to provide insights into the possible mechanical causes of ScT in the early and late phases with data stemming from intracoronary imaging (intravascular ultrasound and optical coherence tomography) of the currently published ScT cases following the implantation of BVS and reviews the practical recommendations for implantation of the BVS made by a group of experts.
No abstract is provided for this article.
Incomplete stent apposition (ISA) has been previously documented after sirolimus-eluting stent (SES) implantation. The aim of this study was to investigate the long-term intravascular ultrasound (IVUS) findings of ISA in patients who received SES.A total of 13 patients who received SES and showed ISA at follow-up IVUS (follow-up I) were investigated. IVUS was performed on all of these patients 12 months later (follow-up II). Quantitative ISA area measurement was also performed at follow-up I and II. No vascular remodeling was observed in the vessel segment with ISA; external elastic membrane area was 19.4+/-6.6 versus 19.5+/-6.4 mm2 at follow-up I and II, respectively. There was also no significant change in external elastic membrane area between vessel segment with ISA and without ISA (+1.5% versus -3.0%, respectively; P=0.27) at late follow-up. The ISA area, either including (2.5+/-1.7 versus 3.8+/-6.3 mm2; P=NS) or excluding (2.5+/-1.8 versus 2.4+/-1.7 mm2; P=NS) a single patient with aneurysm formation, was not significantly different between follow-up I and II. One patient manifested a coronary aneurysm in the stented segment at late follow-up that was probably present at the initial follow-up but masked by thrombus. It was successfully treated with a covered stent. All patients were asymptomatic, and no patient experienced late thrombotic occlusion.Vessel dimensions and area of ISA did not change over time, except for 1 coronary aneurysm that became apparent. ISA after implantation of a SES was not associated with adverse events at late follow-up.
No abstract is provided for this article.
1. The role of platelet-activating factor in the attenuated hypoxic pulmonary vasoconstriction associated with lung injury was evaluated using specific platelet-activating factor antagonists and an isolated perfused lung preparation. 2. Intratracheal bleomycin was administered to rats to produce acute lung injury. Animals received intratracheal saline (control), intratracheal bleomycin or the platelet-activating factor anatagonists BN 52021, WEB 2170 or WEB 2086 before and after bleomycin treatment. Forty-eight hours after intratracheal administration of bleomycin or saline the animals were killed. 3. The increases in pulmonary artery pressure during two periods of hypoxic ventilation and in response to 0.2 μg of angiotensin II were measured. Acetylcholine-induced vasodilatation after pre-constriction with prostaglandin F2α was also measured. To quantify lung injury, the wet/ dry ratio of lung weight was determined. 4. Bleomycin treatment attenuated the first and second hypoxic pressor responses by 93% and 77%, respectively, but not the pressor response to angiotensin II nor the vasodilator response to acetylcholine. BN 52021 plus bleomycin augmented the first hypoxic pressor response compared with bleomycin treatment alone, but the structurally unrelated platelet-activating factor antagonists WEB 2170 and WEB 2086 had no significant effect on the bleomycin-induced attenuation of hypoxic pulmonary vasoconstriction. None of the platelet-activating factor antagonists blocked the increase in the wet/dry lung weight ratio induced by bleomycin. 5. Bleomycin-induced lung injury selectively attenuates hypoxic pulmonary vasoconstriction, an effect that does not appear to be mediated by platelet-activating factor. The mechanism remains to be elucidated, but may involve destruction of the hypoxic ‘sensor’ within the respiratory tract.