Variability in the measurement of minimum fibrous cap thickness and reproducibility of fibroatheroma classification by optical coherence tomography using manual versus semi-automatic assessment
EuroIntervention 12(8): e987-e997
Article 2016 English
Authors
MR
Maria Radu
KY
Kyohei Yamaji
HG
Héctor M. García‐García
Abstract
1 min read
The minimum fibrous cap thickness (FCT) is considered a major criterion of coronary plaque vulnerability according to autopsy studies. We aimed to assess the reproducibility in the measurement of the optical coherence tomography (OCT)-detected minimum FCT and the agreement in the classification of thin-cap fibroatheroma (TCFA), by a software-based semi-automatic method compared with the manual method.A total of 50 frames with fibroatheromas (FA) were randomly selected from the Integrated Biomarker Imaging Study-4 (IBIS-4). Two experienced OCT analysts independently measured the minimum FCT at two different time points, manually and by three different semi-automatic software-based algorithms, based on the assessment of light intensity along the axial scan line. A TCFA was defined as an FA with minimum FCT <65 μm. The inter- and intra-observer reproducibility of the manual measurement of the minimum FCT was moderate with an intra-class correlation coefficient (ICC) of 0.71 and 0.79, respectively. The corresponding ICCs by either one of the three semi-automatic algorithms were 0.99. When categorising FA according to the minimum FCT based on the manual assessment, the inter- and intra-observer agreement was poor (κ=0.23) and moderate (κ=0.50), respectively. In contrast, the semi-automatic assessment showed perfect agreement for both inter- and intra-observer assessments (κ=0.90-1.00 and 1.00, respectively).While semi-automatic assessment of FCT and TCFA classification was associated with excellent reproducibility and agreement, manual measurements were associated with a moderate reproducibility and agreement in the quantification of FCT and classification of TCFA.
Salvatore Brugaletta, Héctor M. García‐García, Josep Gómez‐Lara, Maria Radu, Ravindra Pawar, Jamal Khachabi, Nico Bruining, Manel Sabaté, Patrick W. Serruys
The International Journal of Cardiovascular Imaging
Josep Gómez‐Lara, Salvatore Brugaletta, Roberto Diletti, Bill D. Gogas, Vasim Farooq, Yoshinobu Onuma, Pierre Gobbens, Gerrit Anne van Es, Héctor M. García‐García, Patrick W. Serruys
Yohei Sotomi, Hiroki Tateishi, Pannipa Suwannasom, Jouke Dijkstra, Jeroen Eggermont, Shengnan Liu, Erhan Tenekecioğlu, Yaping Zheng, Mohammad Abdelghani, Rafael Cavalcante, Robbert J. de Winter, Joanna J. Wykrzykowska, Yoshinobu Onuma, Patrick W. Serruys, Takeshi Kimura
The International Journal of Cardiovascular Imaging
Discussion(0)
No comments yet. Be the first to comment.