Three-year clinical and two-year multimodality imaging outcomes of a thin-strut sirolimus-eluting bioresorbable vascular scaffold: MeRes-1 trial
EuroIntervention 15(7): 607-614
Article 2019 English
Authors
AS
Ashok Seth
YO
Yoshinobu Onuma
PC
Praveen Chandra
Abstract
1 min read
Although the proof of concept of the bioresorbable vascular scaffold (BRS) is well documented, device-related adverse outcomes with first-generation BRS indicate longer-term surveillance. The current study provides insights into the safety and performance of the MeRes100, a novel second-generation sirolimus-eluting BRS, beyond one-year up to three-year follow-up (FU).A total of 108 enrolled patients with de novo coronary artery lesions who underwent implantation of MeRes100 as part of the first-in-human MeRes-1 trial were followed up clinically beyond one year at two and three years and with multiple modality imaging at six months and two years. At three-year FU, the cumulative major adverse cardiac events rate was 1.87%, in the form of two ischaemia-driven target lesion revascularisations. No scaffold thrombosis was reported. Between six months and two years at quantitative coronary angiography, in-segment late lumen loss (LLL) (0.15±0.22 mm vs. 0.23±0.32 mm; p=0.18) and in-scaffold LLL (0.13±0.22 mm vs. 0.24±0.34 mm; p=0.10) changed insignificantly. IVUS subset analysis revealed a non-significant reduction in mean lumen area (6.17±1.28 mm2 vs. 5.47±1.50 mm2; p=0.21) and minimum lumen area (5.14±1.19 mm2 vs. 4.05±1.42 mm2; p=0.10) at two years compared to post-procedural measurements. OCT subset analysis demonstrated 99.24±2.27% neointimal strut coverage.The extended outcomes of the MeRes-1 trial demonstrated sustained efficacy and safety of the MeRes100 BRS with maintained lumen patency up to two years by multimodality imaging and no very late scaffold thrombosis up to three-year clinical FU.The MeRes-1 trial is registered at the Clinical Trials Registry-India. CTRI Number: CTRI/2015/04/005706.
Alexandre Abizaid, Saško Kedev, Rosli Bin Mohd Ali, Teguh Santoso, Ángel Cequier, Robert‐Jan Van Geuns van Geuns, Bernard Chevalier, Farrel Hellig, Ricardo A. Costa, Yoshinobu Onuma, J. Ribamar Costa, Patrick W. Serruys, Sripal Bangalore
Yao‐Jun Zhang, Javaid Iqbal, Shimpei Nakatani, Christos V. Bourantas, Carlos M. Campos, Yuki Ishibashi, Yun‐Kyeong Cho, Susan Veldhof, Jin Wang, Yoshinobu Onuma, Héctor M. García‐García, Dariusz Dudek, Robert‐Jan van Geuns, Patrick W. Serruys
Yao‐Jun Zhang, Christos V. Bourantas, Takashi Muramatsu, Javaid Iqbal, Vasim Farooq, Roberto Diletti, Carlos M. Campos, Yoshinobu Onuma, Héctor M. García‐García, Patrick W. Serruys
Patrick W. Serruys, John Ormiston, Robert‐Jan van Geuns, Bernard De Bruyne, Dariusz Dudek, Evald Høj Christiansen, Bernard Chevalier, Pieter Smits, Dougal McClean, Jacques Koolen, Stephan Windecker, Robert Whitbourn, Ian T. Meredith, Luc Wasungu, Divine Ediebah, Susan Veldhof, Yoshinobu Onuma
Discussion(0)
No comments yet. Be the first to comment.