The relationship of pre-procedural Dmax based sizing to lesion level outcomes in Absorb BVS and Xience EES treated patients in the AIDA trial — R. Tijssen (2019) | RDL Network
The relationship of pre-procedural Dmax based sizing to lesion level outcomes in Absorb BVS and Xience EES treated patients in the AIDA trial
The International Journal of Cardiovascular Imaging 35(7): 1189-1198
Article 2019 English
Authors
RT
R. Tijssen
LK
Laura S.M. Kerkmeijer
YK
Yuki Katagiri
Abstract
1 min read
Due to expansion limits of the Absorb bioresorbable scaffold a meticulous implantation with correct sizing is required. We sought to investigate the clinical outcomes based on the sizing of the device related to the maximal lumen diameter measured by quantitative coronary angiography in Absorb BVS and Xience EES treated lesions in the AIDA trial. Sizing of Absorb bioresorbable vascular scaffold (BVS) and Xience everolimus eluting stent (EES) was graded according to the definitions of device non-oversize and device oversize on pre-procedural angiography. Lesion-oriented outcomes (LOCE) (device thrombosis, TLR and TVMI) that occurred during 2 years follow-up were related to device non-oversized or oversized status. In the Absorb BVS group, LOCE occurred in 48 (7.4%) lesions in the oversized group and in 32 (8.2%) lesions in the non-oversized group (HR 0.91; 95% CI 0.58-1.42; p = 0.681), whereas TLR occurred in 34 (5.3%) lesions and in 23 lesions (5.9%), respectively (HR 0.89; 95% CI 0.52-1.51; p = 0.666). Definite scaffold thrombosis occurred in 11 (1.7%) device oversized treated lesions against 16 (4.1%) device non-oversized treated lesions (HR 0.41; 95% CI 0.19-0.89; p = 0.020). There were no differences in event rates between oversized and non-oversized groups in lesions treated with Xience EES. There was no significant difference in LOCE between oversized and non-oversized treated Absorb BVS and Xience EES treated lesions. Non-oversized Absorb BVS implantation was associated with a higher risk of scaffold thrombosis at complete 2 years follow-up. The majority of very late scaffold thrombosis occurred in properly sized devices.
R. Tijssen, René J. van der Schaaf, M Vink, Robin P. Kraak, Sjoerd H. Hofma, E. Karin Arkenbout, Auke Weevers, Laura S.M. Kerkmeijer, Yoshinobu Onuma, Patrick W. Serruys, Jan J. Piek, Jan G.P. Tijssen, José P.S. Henriques, Robbert J. de Winter, Joanna J. Wykrzykowska
Mick Renkens, Maik J. Grundeken, Laura S.M. Kerkmeijer, Robin P. Kraak, Deborah N. Kalkman, René J. van der Schaaf, Sjoerd H. Hofma, Karin Arkenbout, Auke Weevers, Karel T. Koch, Yoshinobu Onuma, Patrick W. Serruys, Jan G.P. Tijssen, Robbert J. de Winter, Joanna J. Wykrzykowska, R. Tijssen
Gregg W. Stone, Takeshi Kimura, Runlin Gao, Dean J. Kereiakes, Stephen G. Ellis, Yoshinobu Onuma, Bernard Chevalier, Charles A. Simonton, Ovidiu Dressler, Aaron Crowley, Ziad A. Ali, Patrick W. Serruys
Salvatore Brugaletta, Tommaso Gori, Adrian F. Low, Petr Toušek, Eduardo Pinar, Josep Gómez‐Lara, Giancarla Scalone, Eberhard Schulz, Mark Y. Chan, Viktor Kočka, José Hurtado, Juan Antoni Gomez-Hospital, Thomas Münzel, Chi‐Hang Lee, Ángel Cequier, Mariano Valdés, Petr Widimský, Patrick W. Serruys, Manel Sabaté
Takashi Muramatsu, Yoshinobu Onuma, Robert‐Jan van Geuns, Bernard Chevalier, Tejas Patel, Ashok Seth, Roberto Diletti, Héctor M. García‐García, Cécile Dorange, Susan Veldhof, Wai-Fung Cheong, Yukio Ozaki, Robert Whitbourn, Antonio L. Bartorelli, Gregg W. Stone, Alexandre Abizaid, Patrick W. Serruys
Discussion(0)
No comments yet. Be the first to comment.