1 min read
Summary form only given. A novel process to implant ions with a grounded conducting grid on top of the wafer stage is described. The implantation is performed in low gas pressure steady state DC mode. The ion paths are numerical simulated by the particle-in-cell (PIC) method. It is observed that the ion paths are optimized for certain implant geometry. In this configuration, the directional angle of the acceleration vector does not depend on the mass and charge state of the ions and the ratio of the partial differentials of the scalar potential /spl phi/ along the radial and longitudinal direction remains constant for different applied voltage. The retained dose and impact energy uniformity on the wafer is totally determined by the ratio of the radius of wafer stage r, the radius of chamber R, the distance between the wafer stage and the grid H, and the thickness of the wafer stage D. Our results suggest that the best ratio of r:R:H:D be 1:4:2.5:2, i.e., a disk shape chamber.