Sizing of the series dynamic breaking resistor in a doubly fed induction generator wind turbine
Article 2014 en
Abstract
1 min read
This paper investigates the effect of Series Dynamic Breaking Resistor (SDBR) sizing on a Doubly Fed Induction Generator (DFIG) based wind power conversion system. The boundary of the SDBR value is firstly derived by taking into account the controllability of the rotor side converter and the maximum allowable voltage of the stator. Then the impact of the SDBR value on the rotor current, stator voltage, DC-link voltage, reactive power capability and introduced power loss during voltage sag operation is evaluated by simulation. The presented study enables a trade-off sizing of the SDBR among the above performance factors.
Discussion(0)