Prospective Assessment of the Diagnostic Accuracy of Instantaneous Wave-Free Ratio to Assess Coronary Stenosis Relevance — Javier Escaned (2015) | RDL Network
Prospective Assessment of the Diagnostic Accuracy of Instantaneous Wave-Free Ratio to Assess Coronary Stenosis Relevance
КАРДИОЛОГИЯ УЗБЕКИСТАНА 8(6): 824-833
Article 2015 English
Authors
JE
Javier Escaned
ME
Mauro Echavarría‐Pinto
HG
Héctor M. García‐García
Abstract
1 min read
The purpose of this study was to assess the diagnostic accuracy of the instantaneous wave-free ratio (iFR) to characterize, outside of a pre-specified range of values, stenosis severity, as defined by fractional flow reserve (FFR) ≤0.80, in a prospective, independent, controlled, core laboratory–based environment. Studies with methodological heterogeneity have reported some discrepancies in the classification agreement between iFR and FFR. The ADVISE II (ADenosine Vasodilator Independent Stenosis Evaluation II) study was designed to overcome limitations of previous iFR versus FFR comparisons. A total of 919 intermediate coronary stenoses were investigated during baseline and hyperemia. From these, 690 pressure recordings (n = 598 patients) met core laboratory physiology criteria and are included in this report. The pre-specified iFR cut-off of 0.89 was optimal for the study and correctly classified 82.5% of the stenoses, with a sensitivity of 73.0% and specificity of 87.8% (C statistic: 0.90 [95% confidence interval (CI): 0.88 to 0.92, p < 0.001]). The proportion of stenoses properly classified by iFR outside of the pre-specified treatment (≤0.85) and deferral (≥0.94) values was 91.6% (95% CI: 88.8% to 93.9%). When combined with FFR use within these cut-offs, the percent of stenoses properly classified by such a pre-specified hybrid iFR-FFR approach was 94.2% (95% CI: 92.2% to 95.8%). The hybrid iFR-FFR approach obviated vasodilators from 65.1% (95% CI: 61.1% to 68.9%) of patients and 69.1% (95% CI: 65.5% to 72.6%) of stenoses. The ADVISE II study supports, on the basis rigorous methodology, the diagnostic value of iFR in establishing the functional significance of coronary stenoses, and highlights its complementariness with FFR when used in a hybrid iFR-FFR approach. (ADenosine Vasodilator Independent Stenosis Evaluation II–ADVISE II; NCT01740895)
Daniel Faria, Joo Myung Lee, Tim van der Hoef, Hernán Mejía‐Rentería, Mauro Echavarría‐Pinto, Sérgio Bravo Baptista, Enrico Cerrato, Héctor M. García‐García, J Davies, Yoshinobu Onuma, Habib Samady, Jan J. Piek, Patrick W. Serruys, Amir Lerman, Javier Escaned
Javier Escaned, Alejandro Travieso, Hakim‐Moulay Dehbi, Sukhjinder Nijjer, Sayan Sen, Ricardo Petraco, Manesh R. Patel, Patrick W. Serruys, Justin E. Davies, Justin E. Davies, Sayan Sen, Hakim‐Moulay Dehbi, Rasha Al‐Lamee, Ricardo Petraco, Sukhjinder Nijjer, Ravinay Bhindi, Sam J. Lehman, D. Walters, James Sapontis, Luc Janssens, Christiaan Vrints, Ahmed Khashaba, Mika Laine, Éric Van Belle, Florian Krackhardt, Waldemar Bojara, Olaf Göing, Tobias Härle, Ciro Indolfi, Giampaolo Niccoli, Flavio Ribichini, Nobuhiro Tanaka, Hiroyoshi Yokoi,
Chee Hae Kim, Bon‐Kwon Koo, Hakim-Moulay Dehbi, Joo Myung Lee, Joon‐Hyung Doh, Chang‐Wook Nam, Eun‐Seok Shin, Christopher Cook, Rasha Al‐Lamee, Ricardo Petraco, Sayan Sen, Iqbal Malik, Sukhjinder Nijjer, Hernán Mejía‐Rentería, Eduardo Alegría‐Barrero, Ali Alghamdi, John D. Altman, Sérgio Bravo Baptista, Ravinay Bhindi, Waldemar Bojara, Salvatore Brugaletta, Pedro Canas Silva, Carlo Di Mario, Andrejs Ērglis,
Zia Ul Sabah, Adel Masswary, Abdullah Mohamed Asiri, Javed Iqbal Wani, Humayoun Khan Durrani, Shahid Aziz, Hafed Ahmad Alaskary, Ali Al Qarni, Ayyub Patel
Discussion(0)