Positive Geometric Vascular Remodeling Is Seen After Catheter-Based Radiation Followed by Conventional Stent Implantation but Not After Radioactive Stent Implantation — I Kay (2000) | RDL Network
Positive Geometric Vascular Remodeling Is Seen After Catheter-Based Radiation Followed by Conventional Stent Implantation but Not After Radioactive Stent Implantation
Circulation 102(12): 1434-1439
Article 2000 English
Authors
IK
I Kay
MS
Manel Sabaté
MC
Marco A. Costa
Abstract
1 min read
Background —Recent reports demonstrate that intracoronary radiation affects not only neointimal formation but also vascular remodeling. Radioactive stents and catheter-based techniques deliver radiation in different ways, suggesting that different patterns of remodeling after each technique may be expected. Methods and Results —We analyzed remodeling in 18 patients after conventional stent implantation, 16 patients after low-activity radioactive stent implantation, 16 patients after higher activity radioactive stent implantation, and, finally, 17 patients who underwent catheter-based radiation followed by conventional stent implantation. Intravascular ultrasound with 3D reconstruction was used after stent implantation and at the 6-month follow-up to assess remodeling within the stent margins and at its edges. Preprocedural characteristics were similar between groups. In-stent neointimal hyperplasia (NIH) was inhibited by high-activity radioactive stent implantation (NIH 9.0 mm 3 ) and by catheter-based radiation followed by conventional stent implantation (NIH 6.9 mm 3 ) compared with low-activity radioactive stent implantation (NIH 21.2 mm 3 ) and conventional stent implantation (NIH 20.8 mm 3 ) ( P =0.008). No difference in plaque or total vessel volume was seen behind the stent in the conventional, low-activity, or high-activity stent implantation groups. However, significant increases in plaque behind the stent (15%) and in total vessel volume (8%) were seen in the group that underwent catheter-based radiation followed by conventional stent implantation. All 4 groups demonstrated significant late lumen loss at the stent edges; however, edge restenosis was seen only in the group subjected to high-activity stent implantation and appeared to be due to an increase in plaque and, to a lesser degree, to negative remodeling. Conclusions —Distinct differences in the patterns of remodeling exist between conventional, radioactive, and catheter-based radiotherapy with stenting.
I Kay, Alexander J. Wardeh, Ken Kozuma, David P. Foley, A.H.M. Knook, Attila Thury, George Sianos, Willem J. van der Giessen, Peter C. Levendag, Patrick W. Serruys
Alexander J. Wardeh, Remo Albiero, I Kay, A.H.M. Knook, William Wijns, Ken Kozuma, Toshihiko Nishida, Valter Ferrero, Peter C. Levendag, Willem J. van der Giessen, Antonio Colombo, Patrick W. Serruys
Alexander J. Wardeh, I Kay, Manel Sabaté, V. Coen, Anthonie L. Gijzel, Jürgen Ligthart, Ad den Boer, Peter C. Levendag, Willem J. van der Giessen, Patrick W. Serruys
Muzaffer Değertekin, Evelyn Regar, Kengo Tanabe, Pedro A. Lemos, Chi‐Hang Lee, Peter Smits, Pim de Feyter, Niko Bruining, Eduardo Sousa, Alexandre Abizaid, Jürgen Ligthart, Patrick W. Serruys
Jiro Aoki, Antonio Colombo, Dariusz Dudek, Adrian Banning, J Drzewiecki, Krzysztof Żmudka, François Schiele, Mary E. Russell, Joerg Koglin, Patrick W. Serruys
Discussion(0)
No comments yet. Be the first to comment.