Skip to content
RDL
Network
Ekosistem
Uygulama değiştir
EN
Hakkımızda
SSS
Giriş yap
Başla
<i>In situ</i> ultrasound imaging of silk hydrogel degradation and neovascularization — Xiaoping Leng (2015) | RDL Network
Back
Cite
Save
Save for later
Share
Home
Publications
<i>In situ</i> ultrasound imaging of silk hydrogel degradation and neovascularization
DK
Shared by
David Kaplan
<i>In situ</i> ultrasound imaging of silk hydrogel degradation and neovascularization
Article
2015
en
Authors
+10 more
XL
Xiaoping Leng
BL
Bin Liu
BS
Bo Su
Abstract
1 min read
Ultrasound (US) is a useful technique to monitor morphological and functional changes of biomaterial implants without sacrificing the animal. Contrast-enhanced ultrasound (CEUS) along with two-dimensional (2D) US were used to characterize the biodegradation and neovascularization of silk protein (8 wt%) hydrogel implants in rats. Cylinder-shaped silk hydrogel plugs were implanted into the space between the hind limb thigh muscles in Wistar rats (n = 6). The increase of echogenicity in 2D US revealed tissue-ingrowth-accompanied gel degradation over 18 weeks. The shape and size of the implanted gels remained qualitatively unchanged until week 15, as confirmed by Bland and Altman analysis and visualization of retrieved samples. Using CEUS, neovascularization was monitored by the presence of microbubbles in the gel area, and the dynamic vascularization process was indicated by the contrast enhancement values, which showed a relatively low level (< 5 dB) during weeks 1-8 and significantly increased levels (around 20 dB at week 15 and > 35 dB at week 18), suggesting that major vascularization had occurred in the gel implants by this time point. Histological and scanning electron microscopic analysis of explants revealed time-dependent increases in the pore size of the gel matrix, the presence of endothelial and red blood cells and the number of blood vessels in the gel implants, indicating that degradation and vascularization did occur in silk gel implants during the time period. The present study demonstrates the use of US imaging for monitoring of in vivo degradation and vascularization of silk implants in a non-destructive way. Copyright © 2015 John Wiley & Sons, Ltd.
Discussion
(0)
Sign in
to like and join the discussion.
No comments yet. Be the first to comment.
Related publications
Article
2019
Vascular Pedicle and Microchannels: Simple Methods Toward Effective In Vivo Vascularization of 3D Scaffolds
Jelena Rnjak‐Kovacina
,
Yi-Wen Gerrand
,
Lindsay S. Wray
,
Beryl Tan
,
Habib Joukhdar
,
David Kaplan
,
Wayne A. Morrison
,
Geraldine M. Mitchell
Article
2013
Photoacoustic microscopy of neovascularization in three-dimensional porous scaffolds<i>in vivo</i>
Xin Cai
,
Yu Zhang
,
Li Li
,
Sung‐Wook Choi
,
Matthew R. MacEwan
,
Junjie Yao
,
Chulhong Kim
,
Younan Xia
,
Lihong V. Wang
Article
2010
Silk hydrogel for cartilage tissue engineering
Pen‐hsiu Grace Chao
,
Supansa Yodmuang
,
Xiaoqin Wang
,
Lin Sun
,
David Kaplan
,
Gordana Vunjak‐Novakovic
Article
2021
Image Guidance in Ablation for Hepatocellular Carcinoma: Contrast-Enhanced Ultrasound and Fusion Imaging
Yasunori Minami
,
Masatoshi Kudo
Article
2020
Enzymatic Degradation of <i>Bombyx mori</i> Silk Materials: A Review
Chengchen Guo
,
Chunmei Li
,
David Kaplan
Discussion(0)
No comments yet. Be the first to comment.