Frequency of Conduction Abnormalities After Transcatheter Aortic Valve Implantation With the Medtronic-CoreValve and the Effect on Left Ventricular Ejection Fraction — Apostolos Tzikas (2010) | RDL Network
Frequency of Conduction Abnormalities After Transcatheter Aortic Valve Implantation With the Medtronic-CoreValve and the Effect on Left Ventricular Ejection Fraction
The American Journal of Cardiology 107(2): 285-289
Article 2010 English
Authors
AT
Apostolos Tzikas
BD
Bas M. van Dalen
NM
Nicolas M. Van Mieghem
Abstract
1 min read
New conduction abnormalities occur frequently after transcatheter aortic valve implantation (TAVI). The relation between new conduction disorders and left ventricular (LV) systolic function after TAVI is unknown. The purpose of the present prospective, single-center study was to investigate the effect of TAVI on LV systolic function in relation to TAVI-induced conduction abnormalities. A total of 27 patients had undergone electrocardiography and transthoracic echocardiography the day before and 6 days after TAVI with the Medtronic-CoreValve system. The LV ejection fraction (EF) was calculated using the biplane Simpson method. The systolic mitral annular velocities and longitudinal strain were measured using speckle tracking echocardiography. After TAVI, 18 patients (67%) had new conduction abnormalities; 4 (15%) had a new paced rhythm and 14 patients (52%) had new left bundle branch block. In the patients with new conduction abnormalities, the EF decreased from 47 ± 12% to 44 ± 10%. In contrast, in those without new conduction abnormalities, the EF increased from 49 ± 12% to 54% ± 12%. The change in EF was significantly different among those with and without new conduction abnormalities (p <0.05). In patients without new conduction abnormalities, an improvement was found in the systolic mitral annular velocities and longitudinal strain (p <0.05). In contrast, in patients with new conduction abnormalities, the changes were not significant. In conclusion, the induction of new conduction abnormalities after TAVI with the Medtronic-CoreValve was associated with a lack of improvement in LV systolic function.
Apostolos Tzikas, Marcel L. Geleijnse, Nicolas M. Van Mieghem, Carl Schultz, Rutger-Jan Nuis, Bas M. van Dalen, Giovanna Sarno, Ron T. van Domburg, Patrick W. Serruys, Peter P.T. de Jaegere
Robert M.A. van der Boon, Nicolas M. Van Mieghem, Dominic A.M.J. Theuns, Rutger‐Jan Nuis, Sjoerd T. Nauta, Patrick W. Serruys, Luc Jordaens, Ron T. van Domburg, Peter P.T. de Jaegere
Nicolò Piazza, Rutger‐Jan Nuis, Apostolos Tzikas, A. Otten, Yoshinobu Onuma, Hector García-García, Carl Schultz, Ron van Domburg, Gerrit-Anne van Es, Robert van Geuns, Peter de Jaegere, Patrick W. Serruys
Robert M.A. van der Boon, Patrick Houthuizen, Marina Ureña, Thomas T. Poels, Nicolas M. Van Mieghem, Guus Brueren, Sibel Altintas, Rutger Nuis, Patrick W. Serruys, Leen van Garsse, Ron T. van Domburg, J. Rodes Cabau, Peter P.T. de Jaegere, Frits W. Prinzen
Carl Schultz, Apostolos Tzikas, Adriaan Moelker, Alexia Rossi, Rutger‐Jan Nuis, M. Geleijnse, Nicolas M. Van Mieghem, Gabriël P. Krestin, Pim de Feyter, Patrick W. Serruys, Peter P. de Jaegere
Discussion(0)
No comments yet. Be the first to comment.