Skip to content
RDL
Network
Ekosistem
Uygulama değiştir
EN
Hakkımızda
SSS
Giriş yap
Başla
Exhaled nitric oxide measurements in normal and asthmatic children — Catherine A. Byrnes (1997) | RDL Network
Back
Cite
Save
Save for later
Share
Home
Publications
Exhaled nitric oxide measurements in normal and asthmatic children
Shared by
Peter J Barnes
Imperial College London
Exhaled nitric oxide measurements in normal and asthmatic children
Article
1997
en
Authors
+2 more
CB
Catherine A. Byrnes
SD
S. Dinarevic
ES
E A Shinebourne
Abstract
1 min read
The aim of this study was to determine whether we could measure exhaled nitric oxide (NO) levels in children, and whether the same pattern of exhaled NO concentrations was observed in asthmatic and normal children as had been seen in adults. Using a chemiluminescence NO analyzer, we measured NO in exhaled air both directly and through a T-piece allowing us to measure carbon dioxide (CO2), mouth pressure, and expiratory flows. In 39 normal children the mean peak exhaled NO was 49.6 parts per billion (ppb) (SD 37.4) when all expired gas passed directly through the NO analyzer, and 29.7 ppb (SD 27.1) when expiration occurred through a T-piece. The results were significantly higher in 15 asthmatic subjects on bronchodilator therapy only [126.1 ppb (SD 77.1) direct (P < 0.001), and 109.5 ppb (SD 106.8) via T-piece (P < 0.001)]. In 16 asthmatics on regular inhaled corticosteroids the mean peak exhaled levels were significantly lower 48.7 ppb (SD 43.3) direct (P < 0.001) and 45.2 ppb (SD 45.9) via T-piece (P < 0.01). There was no difference between the normal children and the asthmatic children on regular inhaled corticosteroids (P = 0.9 direct, P = 0.2 via T-piece). There were no significant differences in carbon dioxide levels, mouth pressure, duration of expiration and expiratory flows between the different groups, and no difference between carbon dioxide levels, mouth pressure and duration of expiration between the two methods (direct and T-piece). In 6 asthmatic children mean peak exhaled levels on NO fell from a median peak level of 124.5 ppb to 48.6 ppb when measured before and 2 weeks after commencement of inhaled corticosteroid treatment. The measurement of exhaled NO levels may be useful as a noninvasive means of monitoring children with asthma. Pediatr. Pulmonol. 1997; 24:312–318 © 1997 Wiley-Liss, Inc.
Discussion
(0)
Sign in
to like and join the discussion.
No comments yet. Be the first to comment.
Related publications
Article
1997
Exhaled nitric oxide measurements in normal and asthmatic children
Catherine A. Byrnes
,
S. Dinarevic
,
E A Shinebourne
,
Peter J Barnes
,
Andrew Bush
Article
1996
Increased exhaled nitric oxide in asthma is mainly derived from the lower respiratory tract.
Sergei A. Kharitonov
,
Kian Fan Chung
,
David J. Evans
,
Brian O’Connor
,
Peter J Barnes
Article
1999
Effect of inhaled ozone on exhaled nitric oxide, pulmonary function, and induced sputum in normal and asthmatic subjects
Julia A. Nightingale
,
D. F Rogers
,
Peter J Barnes
Article
1998
Prostaglandins E<sub>2</sub>and F<sub>2 α</sub>Reduce Exhaled Nitric Oxide in Normal and Asthmatic Subjects Irrespective of Airway Caliber Changes
Sergei A. Kharitonov
,
MARIA A. SAPIENZA
,
Peter J Barnes
,
Kian Fan Chung
Article
1995
Elevated levels of exhaled nitric oxide in bronchiectasis.
Sergei A. Kharitonov
,
Athol U. Wells
,
Brian O’Connor
,
Peter Cole
,
D.M. Hansell
,
R B Logan-Sinclair
,
Peter J Barnes
Discussion(0)
No comments yet. Be the first to comment.