Evaluation of Three-Phase Transformerless DC-Bypass PV Inverters for Leakage Current Reduction
Article 2019 en
Abstract
1 min read
In transformerless photovoltaic (PV) systems, the leakage current reduction is one of the most important issues. Many interesting single-phase dc-bypass transformerless PV inverters have been proposed for the leakage current reduction, and there is a well-known conclusion that the clamping topology is better than the unclamping one in terms of leakage current reduction. However, is this conclusion correct for three-phase dc-bypass ones? The main objective of this article is to investigate the impact of clamping and unclamping dc-bypass switches on the leakage current reduction capability of three-phase transformerless inverters. The findings reveal that the conclusion is different from the single-phase dc-bypass ones. The theoretical analysis and experimental results are provided to verify the new insights.