Abstract
1 min read
© 2017 IEEE. Harmonic and interharmonic distortions are considered as the main power quality issues especially in the distribution networks. The double-stage Adjustable Speed Drives (ASDs) in which the front-end diode rectifier is connected to a rear-end inverter through an intermediate DC-link filter May inject significant amount of harmonics and interharmonics into the grid and consequently degrade the grid power quality. In this paper, the effect of the DC-link filter – as a key player – on the ASD input current harmonic and interharmonic distortions is investigated. In this respect, the ASD performance is evaluated harmonically based on three different DC-link configurations; the conventional filter (with AC- and/or DC-side chokes, and DC-link capacitor), the Small DC-Link Capacitor (SDLC), and the controlled DC link by using an Electronic Inductor (EI) technique. It shows how employing the small DC-link capacitor will push the harmonics into the higher frequency ranges and it will also give rise to more interharmonic distortions. Moreover, the EI configuration is introduced as an optimal DC-link intermediate circuit within the investigated frequency range of 0–2 kHz. The presented analysis and discussions have been validated by the simulation and experimental results.
Discussion
(0)
Sign in
to like and join the discussion.
No comments yet. Be the first to comment.
Related publications
Article
2015
Interharmonic mitigation of adjustable speed drives using an active DC-link capacitor
Article
2017
Performance evaluation of electronic inductor based adjustable speed drives with respect to line current interharmonics
Article
2017
Load‐independent harmonic mitigation in SCR‐fed three‐phase multiple adjustable speed drive systems with deliberately dispatched firing angles
Article
2017
Harmonic distortion performance of multi three-phase SCR-fed drive systems with controlled DC-link current under unbalanced grid
Article
2017
Harmonic Emissions of Three-Phase Diode Rectifiers in Distribution Networks
Discussion(0)
No comments yet. Be the first to comment.