Corrosion resistance and antithrombogenic behavior of La and Nd ion implanted stainless steels
Article 2006 en
Authors
FJ
F.J. Jing
FJ
Fuxiang Jin
YL
Y. W. Liu
Abstract
1 min read
Lanthanide ions such as lanthanum (La) and neodymium (Nd) were implanted into 316 stainless steel samples using metal vapor vacuum arc to improve the surface corrosion resistance and antithrombogenic properties. X-ray photoelectron spectroscopy shows that lanthanum and neodymium exist in the +3 oxidation state in the surface layer. The corrosion properties of the implanted and untreated control samples were investigated utilizing electrochemical tests and our results show that La and Nd implantations enhance the surface corrosion resistance. In vitro activated partial thromboplastin time (APTT) tests were used to evaluate the antithrombogenic properties. The APTT time of the implanted samples was observed to be prolonged compared to that of the unimplanted stainless steel control. La and Nd ion implantations can be used to improve the surface corrosion resistance and biomedical properties of 316 stainless steels.
F.J. Jing, Nan Huang, Y. W. Liu, Wenjun Zhang, Xuebo Zhao, Ricky K.Y. Fu, Jingyue Wang, Zhen Yi Shao, J. Y. Chen, Y.X. Leng, Xiaoyi Liu, Paul Kim Ho Chu
Discussion(0)
No comments yet. Be the first to comment.