Comparison of Newer-Generation Drug-Eluting With Bare-Metal Stents in Patients With Acute ST-Segment Elevation Myocardial Infarction
КАРДИОЛОГИЯ УЗБЕКИСТАНА 7(1): 55-63
Article 2013 English
Authors
MS
Manel Sabaté
LR
Lorenz Räber
DH
Dik Heg
Abstract
2 min read
Objectives
This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI).
Background
Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES.
Methods
Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year.
Results
Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS.
Conclusions
Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.
Ply Chichareon, Rodrigo Modolo, Carlos Collet, Erhan Tenekecioğlu, M Vink, Pyung Chun Oh, Jung‐Min Ahn, Carmine Musto, Luis S. Díaz de la Llera, Young‐Seok Cho, Roberto Violini, Seung‐Jung Park, Harry Suryapranata, Jan J. Piek, Robbert J. de Winter, Joanna J. Wykrzykowska, Christian Spaulding, Woong Chol Kang, Ton Slagboom, Sjoerd H. Hofma, Inge Wijnbergen, Emilio Di Lorenzo, Nico H.J. Pijls, Lorenz Räber, Salvatore Brugaletta, Manel Sabaté, Hans-Peter Stoll, Gregg W. Stone, Stephan Windecker, Yoshinobu Onuma, Patrick W. Serruys
Manel Sabaté, Ángel Cequier, Andrés Íñiguez, Antonio Serra, Rosana Hernández‐Antolín, Vicente Mainar, Marco Valgimigli, Maurizio Tespili, Pieter den Heijer, Armando Bethencourt, Nicolás Vazquez, Joan Antoni Gómez‐Hospital, José Antonio Baz, Victoria Martín‐Yuste, Robert‐Jan van Geuns, Fernándo Alfonso, Pascual Bordes, Matteo Tebaldi, Mónica Masotti, Antonio Silvestro, Bianca Backx, Salvatore Brugaletta,
Discussion(0)
No comments yet. Be the first to comment.