Comparison of acute gain and late lumen loss after PCI with bioresorbable vascular scaffolds versus everolimus-eluting stents: an exploratory observational study prior to a randomised trial — Yao‐Jun Zhang (2014) | RDL Network
Comparison of acute gain and late lumen loss after PCI with bioresorbable vascular scaffolds versus everolimus-eluting stents: an exploratory observational study prior to a randomised trial
EuroIntervention 10(6): 672-680
Article 2014 English
Authors
YZ
Yao‐Jun Zhang
CB
Christos V. Bourantas
TM
Takashi Muramatsu
Abstract
1 min read
The study sought to compare the acute gain and two-year follow-up late lumen loss (LLL) between the Absorb bioresorbable vascular scaffold (BVS) and the analogous everolimus-eluting metallic stent (EES). The current analysis included all the patients recruited in the ABSORB Cohort B and SPIRIT II trials implanted with a single 3.0×18 mm device (Absorb BVS or EES) who underwent serial angiographic examinations at baseline and at two-year follow-up. The acute gain was defined as the difference between post- and preprocedural minimal lumen diameter (MLD). The in-stent/scaffold LLL was calculated as the difference in stent/scaffold segment between the post-procedural MLD and follow-up MLD. Thirty-three patients (33 lesions) implanted with the Absorb BVS, and 26 patients (28 lesions) implanted with the EES were studied. The acute gain was similar in the Absorb BVS group (1.23±0.38 mm) compared to the EES group (1.32±0.26 mm, p=0.29). The in-stent/scaffold LLL at two-year follow-up in the Absorb BVS group (0.26±0.19 mm) was also similar compared to the EES group (0.22±0.22 mm, p=0.29). Although the two groups had similar two-year clinical outcomes (major adverse cardiac events: Absorb BVS: 6.1% vs. EES: 0.0%), patients treated with the Absorb BVS exhibited a significantly lower two-year in-stent/scaffold MLD compared to the EES (2.02±0.26 mm vs. 2.22±0.34 mm, p=0.01). Although BVS and EES demonstrated similar two-year clinical outcomes, patients treated with the Absorb BVS exhibited a significantly lower two-year in-stent/scaffold MLD compared to patients treated with the EES. Appropriately powered randomised trials are necessary to confirm these exploratory results and evaluate their prognostic and clinical significance.
Yoshinobu Onuma, Patrick W. Serruys, J.A. Fernández Gómez, Bernard De Bruyne, Dariusz Dudek, Leif Thuesen, Peter Smits, Bernard Chevalier, Dougal McClean, Jacques Koolen, Stephan Windecker, Robert Whitbourn, Ian T. Meredith, Héctor M. García‐García, John A. Ormiston
Takashi Muramatsu, Yoshinobu Onuma, Robert‐Jan van Geuns, Bernard Chevalier, Tejas Patel, Ashok Seth, Roberto Diletti, Héctor M. García‐García, Cécile Dorange, Susan Veldhof, Wai-Fung Cheong, Yukio Ozaki, Robert Whitbourn, Antonio L. Bartorelli, Gregg W. Stone, Alexandre Abizaid, Patrick W. Serruys
Salvatore Cassese, Robert A. Byrne, Peter Jüni, Joanna J. Wykrzykowska, Serban Puricel, Gjin Ndrepepa, Heribert Schunkert, Massimiliano Fusaro, Stéphane Cook, Takeshi Kimura, José P.S. Henriques, Patrick W. Serruys, Stephan Windecker, Adnan Kastrati
Discussion(0)