Abstract
1 min read
Fully bioresorbable Absorb poly-L-lactic-acid (PLLA) scaffolds (Abbott Vascular, Santa Clara, CA, USA) are a novel approach for the treatment of coronary narrowing. Due to the translucency of the material (PLLA), the optical coherence tomography (OCT) measurement methods used in the ABSORB trials were unique but not applicable for permanent metallic stents. When the Absorb scaffold and metallic stents are compared in the context of randomised trials, it is challenging to compare the two devices using the conventional methods. The primary purpose of this report is to explain the biases in conventional methodologies applied for metallic stents and for PLLA scaffolds at baseline and follow-up, and to propose a new standard methodology that enables us to compare two different devices using an almost identical and methodological language.A consensus amongst multiple core labs and expert researchers of OCT was reached on a new standard OCT measurement methodology that enables us to compare these two different devices. In brief, the proposed OCT methods are summarised as follows. 1) Both endoluminal and abluminal scaffold/stent contours should be traced. 2) Consistently, endoluminal and abluminal incomplete stent apposition areas should be measured. 3) The area occupied by scaffold/stent struts should be quantified directly or virtually. 4) The strut area should be systematically excluded from the flow area as well as the neointimal area. 5) Additional information on the degree of embedment could be reported using the interpolated lumen contour. Interobserver variability of the proposed method was excellent (intraclass correlation 0.89-100).A standardised OCT measurement methodology is proposed. This should be implemented in ongoing and future trials comparing the Absorb scaffolds and metallic stents.
Josep Gómez‐Lara, Salvatore Brugaletta, Vasim Farooq, Yoshinobu Onuma, Roberto Diletti, Stephan Windecker, Leif Thuesen, Dougal McClean, Jacques Koolen, Robert Whitbourn, Dariusz Dudek, Pieter C. Smits, Bernard Chevalier, Evelyn Regar, Susan Veldhof, Richard Rapoza, John A. Ormiston, Héctor M. García‐García, Patrick W. Serruys
Patrick W. Serruys, Yuki Katagiri, Yohei Sotomi, Yaping Zeng, Bernard Chevalier, René J. van der Schaaf, Andreas Baumbach, Pieter C. Smits, Nicolas M. Van Mieghem, Antonio L. Bartorelli, Paul Barragan, Anthony Gershlick, Ran Kornowski, Carlos Macaya, John A. Ormiston, Jonathan Hill, Iréne Lang, Mohaned Egred, Jean Fajadet, Maciej Lesiak, Stephan Windecker, Robert A. Byrne, Lorenz Räber, Robert‐Jan van Geuns,
Discussion(0)
No comments yet. Be the first to comment.