Capture of circulatory endothelial progenitor cells and accelerated re-endothelialization of a bio-engineered stent in human ex vivo shunt and rabbit denudation model — Katarína Larsen (2011) | RDL Network
Capture of circulatory endothelial progenitor cells and accelerated re-endothelialization of a bio-engineered stent in human ex vivo shunt and rabbit denudation model
European Heart Journal 33(1): 120-128
Article 2011 English
Authors
KL
Katarína Larsen
CC
Caroline Cheng
DT
Dennie Tempel
Abstract
1 min read
The Genous™ Bio-engineered R™ stent (GS) aims to promote vascular healing by capture of circulatory endothelial progenitor cells (EPCs) to the surface of the stent struts, resulting in accelerated re-endothelialization. Here, we assessed the function of the GS in comparison to bare-metal stent (BMS), when exposed to the human and animal circulation.First, 15 patients undergoing coronary angiography received an extracorporeal femoral arteriovenous (AV) shunt containing BMS and GS. Macroscopical mural thrombi were observed in BMS, whereas GS remained visibly clean. Confocal and scanning electron microscopic (SEM) analysis of GS showed an increase in strut coverage. Quantitative polymerase chain reaction (qPCR) analysis of captured cells on the GS demonstrated increased expression of endothelial markers KDR/VEGFR2 and E-selectin, and a decrease in pro-thrombogenic markers tissue factor pathway inhibitor and plasminogen activator inhibitor-1 compared with BMS. Secondly, a similar primate AV shunt model was used to validate these findings and occlusion of BMS was observed, while GS remained patent, as demonstrated by live imaging of indium-labelled platelets. Thirdly, in an in vitro cell-capture assay, GS struts showed increased coverage by EPCs, whereas monocyte coverage remained similar to BMS. Finally, the assessment of re-endothelialization was studied in a rabbit denudation model. Twenty animals received BMS and GS in the aorta and iliac arteries for 7 days. Scanning electron microscopic analysis showed a trend towards increased strut coverage, confirmed by qPCR analysis revealing increased levels of endothelial markers (Tie2, CD34, PCD31, and P-selectin) in GS.In this proof-of-concept study, we have demonstrated that the bio-engineered EPC-capture stent, Genous™ R™ stent, is effective in EPC capture, resulting in accelerated re-endothelialization and reduced thrombogenicity.
Jiro Aoki, Patrick W. Serruys, Heleen van Beusekom, Andrew T.L. Ong, Eugène McFadden, Georgios Sianos, Willem J. van der Giessen, Evelyn Regar, Pim J. de Feyter, H Richard Davis, Stephen Rowland, Michael J.B. Kutryk
Nicolas Foin, Juan Luis Gutiérrez‐Chico, Shimpei Nakatani, Ryo Torii, Christos V. Bourantas, Sayan Sen, Sukhjinder Nijjer, Ricardo Petraco, Chrysa A. Kousera, Matteo Ghione, Yoshinobu Onuma, Héctor M. García‐García, Dárrel P. Francis, Philip Wong, Carlo Di Mario, Justin E. Davies, Patrick W. Serruys
David M. Smadja, David M. Smadja, Ivan Bièche, Ivan Bièche, Dominique Helley, Dominique Helley, Ingrid Laurendeau, Ingrid Laurendeau, Ghislaine Simonin, Ghislaine Simonin, Laurent Muller, Laurent Muller, Martine Aiach, Martine Aiach, Pascale Gaussem, Pascale Gaussem
Discussion(0)
No comments yet. Be the first to comment.