Addressing the unbalance loading issue in multi-drive systems with a DC-link modulation scheme for harmonic reduction
Article
2016
en
Abstract
1 min read
© 2016 IEEE. Concerning cost, volume, and efficiency, Adjustable Speed Drive (ASD) systems are commonly employed with diode rectifiers or Silicon Controlled Rectifiers (SCR) as the front-ends (i.e., ac-dc converters). Apart from low cost, small volume, and high reliability, harmonic currents are significantly produced at the grid side by the rectification apparatus (i.e., diode rectifiers or SCR). As a simple strategy, the phase-shifted current control can be applied to the SCR-fed drive systems, where the input currents for the SCR are phase-shifted in such a way to cancel out the harmonics of interest (e.g., the 5th order harmonic). However, this solution is effective only when same amounts of currents are drawn by the rectifiers. Unfortunately, in practice, the loading is different among the parallel drive systems, leading to degradation in the harmonic mitigation. In this paper, unequal loading conditions in multi-drive systems are thus addressed. A load-adaptive scheme by means of varying the dc-link voltage is proposed, where a unified dc-link current modulation scheme is also employed in the dc-link. The proposed load-adaptive scheme can ensure that the rectified currents (i.e., rectifier output currents) are equal, and thus the harmonic reduction enabled by the phase-shifted current control is enhanced. The principle of the proposed method is demonstrated on a two-drive system consisting of a diode rectifier and a SCR. Experimental tests have validated the effectiveness of the proposed scheme in terms of harmonic mitigation for multiple parallel ASD systems.
Discussion
(0)
Sign in
to like and join the discussion.
No comments yet. Be the first to comment.
Related publications
Article
2015
A DC-Link Modulation Scheme With Phase-Shifted Current Control for Harmonic Cancellations in Multidrive Applications
Article
2016
Enhanced Phase-Shifted Current Control for Harmonic Cancellation in Three-Phase Multiple Adjustable Speed Drive Systems
Article
2017
Load‐independent harmonic mitigation in SCR‐fed three‐phase multiple adjustable speed drive systems with deliberately dispatched firing angles
Article
2016
Deliberately dispatched SCR firing angles for harmonic mitigation in three-phase multi-drive systems without communication
Article
2015
A smart current modulation scheme for harmonic reduction in three-phase motor drive applications