A comparison of six methods for measuring soil-surface carbon
Article 1997 en
Authors
JN
John M. Norman
CK
Christopher J. Kucharik
SG
Stith T. Gower
Abstract
1 min read
Measurements of soil-surface CO2 fluxes are important for characterizing the carbon budget of boreal forests because these fluxes can be the second largest component of the budget. Several methods for measuring soil-surface CO2 fluxes are available' (1) closed-dynamic-chamber systems, (2) closed-static-chamber systems, (3) open-chamber systems, and (4) eddy covariance systems. This paper presents a field comparison of six individual systems for measuring soil-surface CO2 fluxes with each of the four basic system types represented. A single system is used as a reference and compared to each of the other systems individually in black spruce (Picea mariana), jack pine (Pinus banksiana), or aspen (Populus tremuloides) forests. Fluxes vary from 1 to 10/mol CO2 m -2 s -. Adjustment factors to bring all of the systems into agreement vary from 0.93 to 1.45 with an uncertainty of about 10-15%.
Patrick Büker, Tim Morrissey, A. Briolat, Richard H. Falk, David Simpson, J.-P. Tuovinen, Rocı́o Alonso, S. Barth, Manuela Baumgarten, N. E. Grulke, Per Erik Karlsson, John S. King, F. Lagergren, Rainer Matyssek, Angela J. Nunn, Romà Ogaya, Josep Penuelas, Lee Rhea, Marcus Schaub, Johan Uddling, Willy Werner, Lisa Emberson