55 Use of the index beat method to improve the echocardiographic assessment of cardiac function in patients with atrial fibrillation — Karina V Bunting (2020) | RDL Network
55 Use of the index beat method to improve the echocardiographic assessment of cardiac function in patients with atrial fibrillation
Article 2020 en
Authors
KB
Karina V Bunting
SG
Simrat Gill
AS
Alice Sitch
Abstract
2 min read
<h3>Introduction</h3> Echocardiography is essential for the management of patients with atrial fibrillation (AF), but current methods are time consuming and lack any evidence of reproducibility. <h3>Purpose</h3> To compare conventional averaging of consecutive beats with an index beat approach, where systolic and diastolic measurements are taken once after two prior beats with a similar RR interval (not more than 60 ms difference). <h3>Methods</h3> Transthoracic echocardiography was performed using a standardized and blinded protocol in patients enrolled into the RAte control Therapy Evaluation in permanent AF randomised controlled trial (RATE-AF; NCT02391337). AF was confirmed in all patients with a preceding 12-lead ECG. A minimum of 30-beat loops were recorded. Left ventricular function was determined using the recommended averaging of 5 and 10 beats and using the index beat method, with observers blinded to clinical details. Complete loops were used to calculate the within-beat coefficient of variation (CV) and intraclass correlation coefficient (ICC) for Simpson’s biplane left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and filling pressure (E/e’). <h3>Results</h3> 160 patients (median age 75 years (IQR 69-82); 46% female) were included, with median heart rate 100 beats/min (IQR 86-112). For LVEF, the index beat had the lowest CV of 32% compared to 51% for 5 consecutive beats and 53% for 10 consecutive beats (p<0.001). The index beat also had the lowest CV for GLS (26% versus 43% and 42%; p<0.001) and E/e’ (25% versus 41% and 41%; p<0.001; see Figure for ICC comparison). Intra-operator reproducibility, assessed by the same operator from two different recordings in 50 patients, was superior for the index beat with GLS bias -0.5 and narrow limits of agreement (-3.6 to 2.6), compared to -1.0 for 10 consecutive beats (-4.0 to 2.0). For inter-operator variability, assessed in 18 random patients, the index beat also showed the smallest bias with narrow confidence intervals (CI). Using a single index beat did not impact on the validity of LVEF, GLS or E/e’ measurement when correlated with natriuretic peptides. Index beat analysis substantially shortened analysis time; 35 seconds (95% CI 35 to 39 seconds) for measuring E/e’ with the index beat versus 98 seconds (95% CI 92 to 104 seconds) for 10 consecutive beats (see Figure 1). <h3>Conclusion</h3> Index beat determination of left ventricular function improves reproducibility, saves time and does not compromise validity compared to conventional quantification in patients with heart failure and AF. After independent validation, the index beat method should be adopted into routine clinical practice. <h3>Conflict of Interest</h3> Nothing to declare
Karina V Bunting, Sharon A. Gill, Alice Sitch, Samir Mehta, K. O’Connor, James Hodson, Professor Gregory Lip, Martha Stanbury, Paulus Kirchhof, Megan M. Griffith, John Townend, Richard P. Steeds, Dipak Kotecha
Karina V Bunting, Simrat Gill, Alice Sitch, Samir Mehta, Kieran O’Connor, Professor Gregory Lip, Paulus Kirchhof, Victoria Y. Strauss, Kazem Rahimi, A. John Camm, Mary Stanbury, Michael Griffith, John Townend, Georgios V. Gkoutos, Andreas Karwath, Richard P. Steeds, Dipak Kotecha
Valeria Rella, Caterina Delcea, Alexandra Clément, Samantha Fisicaro, Federica Perelli, Michele Tomaselli, Marco Penso, Gianfranco Parati, Lia Crotti, Luigi P. Badano, Denisa Muraru
Discussion(0)
No comments yet. Be the first to comment.