6,963 publications from this institution
The behaviour and design of cylindrically-pinned stainless steel equal-leg angle section members under compression and compression combined with strong-axis bending are investigated herein. An experimental investigation, including material testing, initial geometric imperfection measurements and physical tests on hot-rolled stainless steel equal-leg angle section members is first presented. Numerical models are developed by means of shell finite element modelling formulated within ABAQUS and validated against experimental data. A numerical parametric study is then presented considering both hot-rolled and cold-formed stainless steel equal-leg angle section columns alongside beam–columns with a wide range of cross-section and member geometries. Finally, new design proposals for cylindrically-pinned stainless steel equal-leg angle section members under compression and compression plus major-axis bending are developed and verified against the results of physical experiments and numerical simulations. The proposed design rules are shown to offer substantially more accurate and consistent resistance predictions compared to existing codified design rules. The reliability of the new design provisions, with a recommended partial safety factor γM1=1.1, is verified following the EN 1990 procedure.
tiotropium bromide provides long term bronc-There have been important advances in mus-Thoracic Medicine, National Heart and hodilatation and protection against cholinergic carinic receptor pharmacology with the re-Lung Institute, challenge in asthmatic subjects with effects lastcognition of several subtypes of muscarinic Imperial College, ing for more than three days. 11In studies of receptors in airways which appear to serve London SW3 6LY, UK patients with COPD tiotropium bromide gives P J Barnes different physiological functions. 4This has sugprolonged bronchodilatation lasting over 24 gested that more selective muscarinic ant-Correspondence to: Professor P J Barnes.agonists may have advantages over the existing hours. 12 13This suggests that tiotropium brom-
We studied the effect of vasoactive intestinal peptide (VIP) on the output of 35S-labeled macromolecules from ferret tracheal explants either placed in beakers or suspended in modified Ussing chambers. In Ussing chamber experiments, the radiolabel precursor, sodium [35S]sulfate, and all drugs were placed on the submucosal side of the tissue. Washings were collected at 30-min intervals from the luminal side and were dialyzed to remove unbound 35S, leaving radiolabeled macromolecules. Vasoactive intestinal peptide at 3 × 10−7 M stimulated bound 35S output by a mean of +252.6% (n = 14). The VIP response was dose-dependent with a near maximal response and a half maximal response at approximately 10−6 M and 10−8, M, respectively. The VIP effect was not inhibited by a mixture of tetrodotoxin, atropine, l-propranolol, and phentolamine. Vasoactive intestinal peptide had no effect on the electrical properties of the tissues. We conclude that VIP stimulates output of sulfated-macromolecules from ferret tracheal submucosal glands without stimulating ion transport. Our studies also suggest that VIP acts on submucosal glands via specific VIP receptors. Vasoactive intestinal peptide has been shown to increase intracellular levels of cyclic AMP, and we suggest that this may be the mechanism for its effect on the output of macromolecules. This mechanism may be important in the neural regulation of submucosal gland secretion.
Background In patients with three-vessel disease and/or left main disease, selecting revascularization strategies based on coronary computed tomography angiography (CCTA) has a high level of virtual agreement with treatment decisions based on invasive coronary angiography(ICA).(1) Purpose The FASTTRACK CABG trial aims to assess the feasibility and safety of using CCTA and FFRCT as guidance for planning and performing CABG in patients with 3VD and/or LMCAD. Methods In this multicentre study, coronary artery bypass grafts (CABG) were planned and performed based on CCTA without knowledge of ICA. CABG strategy was recommended by a central Core laboratory assessing the anatomy and functionality of the coronary circulation. The primary feasibility endpoint was the percentage of operations performed without access to the ICA. The primary safety endpoint was graft patency on 30-day follow-up CCTA. Secondary endpoints included topographical adequacy of grafting, major adverse cardiac and cerebrovascular events (MACCE), and major bleeding events at 30 days. The study was considered positive if the lower boundary of confidence intervals(CI) for feasibility ≥75%.(2) Results The study enrolled 114 patients with a mean (standard deviation) anatomical SYNTAX Score and Society of Thoracic Surgery score of 43.6 (15.3) and 0.81 (0.63), respectively. Three patients did not undergo CABG due to the patient’s preference for percutaneous treatment (n=1) or lack of graft material. Unblinding ICA was required in one case, yielding a feasibility of 99.1% (95%CI: 95.2%-100%). The concordance and agreement in revascularization planning between the ICA- and CCTA-Heart Team was 82.9% with a moderate kappa of 0.58 (95%CI:0.50-0.66). The concordance and agreement in revascularization planning between the CCTA-Heart Team and actual treatment was 83.7% with a substantial kappa of 0.61 (95%CI:0.53-0.68). The 30-day follow-up CCTA was performed in 102 (91.9%) of the 111 operated patients, which showed an anastomosis patency rate of 92.6%. At 30 days, the incidence of MACCE was 7.2% whereas major bleeding was 2.7%. Conclusions CABG guided by CCTA is feasible and has an acceptable safety profile in a selected population of complex coronary artery disease.
Background: The ABSORB Cohort B trial is a continuation of the ABSORB Cohort A trial in the assessment of the safety and performance of a modified ABSORB Everolimus Eluting Vascular Scaffold (Abbot...
Background— The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified. Methods and Results— Quantitative coronary angiography, intravascular ultrasound with analysis of radiofrequency backscattering, and as an optional assessment, optical coherence tomography (OCT) were performed at baseline and at a 6-month follow-up. Forty-five patients successfully received a single bioresorbable everolimus drug-eluting vascular scaffold. One patient had postprocedural release of myocardial enzyme without Q-wave occurrence; 1 patient with OCT-diagnosed disruption of the scaffold caused by excessive postdilatation was treated 1 month later with a metallic drug-eluting stent. At follow-up, 3 patients declined recatheterization, 42 patients had quantitative coronary angiography, 37 had quantitative intravascular ultrasound, and 25 had OCT. Quantitative coronary angiography disclosed 1 edge restenosis (1 of 42; in-segment binary restenosis, 2.4%). At variance with the ultrasonic changes seen with the first generation of bioresorbable everolimus drug-eluting vascular scaffold at 6 months, the backscattering of the polymeric struts did not decrease over time, the scaffold area was reduced by only 2.0% with intravascular ultrasound, and no change was noted with OCT. On an intention-to-treat basis, the late lumen loss amounted to 0.19±0.18 mm with a limited relative decrease in minimal luminal area of 5.4% on intravascular ultrasound. OCT showed at follow-up that 96.8% of the struts were covered and that malapposition of at least 1 strut, initially observed in 12 scaffolds, was detected at follow-up in only 3 scaffolds. Mean neointimal growth measured by OCT between and on top of the polymeric struts equaled 1.25 mm 2 , or 16.6% of the scaffold area. Conclusion— Modified manufacturing process of the polymer and geometric changes in the polymeric platform have substantially improved the medium-term performance of this new generation of drug-eluting scaffold to become comparable to those of current drug eluting stents. Clinical Trial Registration— URL: http://clinicaltrials.gov . Unique identifier: NCT00856856.