Extract: Asthma has now become one of the most common chronic diseases in industrialized countries and is predicted to increase throughout the world over the next decade, particularly in developing countries. Previously, asthma was viewed as a disease of bronchoconstriction (closing of the airways) and treated predominantly with bronchodilators (drugs which open up the airways), but more recently it has been seen as an inflammatory disease of the airways and the mainstay of modern management is treatment with inhaled corticosteroids. The airway inflammation in asthma is characterized by activation of mast cells, infiltration of eosinophils and increased activated T helper 2 (Th2) lymphocytes. Inhaled corticosteroids have revolutionized the management of asthma, leading to better control of asthma, reduced hospital admissions and a reduced mortality. Corticosteroids and long-acting beta2-agonists (salmeterol and formoterol) in fixed combination inhalers are currently the most effective therapy for asthma and are increasingly used in all patients with persistent symptoms.
No abstract is provided for this article.
Towards the development of more resilient and sustainable structures, interest in the use of high performance construction materials, such as stainless steels, has increased in recent years. Recent studies [1] have highlighted a number of deficiencies in the flexural buckling provisions given in Eurocode 3: Part 1.4 for the design of stainless steel compression members. Therefore, this study aims to investigate the effect of production route (cold-formed and hot-finished) and material grade (austenitic, duplex and ferritic) on the behaviour and design of stainless steel square and rectangular hollow section columns. Test data from the literature combined with numerical modelling data generated as part of this study are used to derive a series of buckling curves for the design of stainless steel columns. Reliability analysis in accordance with Annex D of EN 1990 has been carried out to show that the proposed buckling curves comply with the Eurocode reliability requirements.
No abstract is provided for this article.
We have tested the performance of an Optotrak Certus system, which optically tracks multiple markers, in both position and time. To do this, we have developed custom code which enables a range of testing protocols, and make this code available to the community. We find that the Certus' positional accuracy is very high, around 20 µm at a distance of 2.8 m. In contrast, we find that its timing accuracy is typically no better than around 5–10% for typical data rates, whether one is using an ethernet connection or a dedicated SCSI link from the system to a host computer. However, with our code we are able to attach very accurate timestamps to the data frames, and in cases where regularly-spaced data are not an absolute requirement, this will be more than adequate.
There has been intense research into the role nitric oxide (NO) plays in physiological and pathological mechanisms and its clinical significance in respiratory medicine. Elevated levels of exhaled levels of exhaled NO in asthma and other inflammatory lung diseases lead to many studies examining NO as potential markers of airway inflammation, enabling repeated noninvasive and standardized monitoring of airway inflammation. In airway inflammation, NO is not merely a marker but may have anti- inflammatory and pro-inflammatory effects. Significant correlation has been found between exhaled NO and skin test scores in steroid naive asthmatic patients, allowing to discriminate patients with and without airway responsiveness. Exhaled NO is significantly elevated in acute asthma, or steroid-resistant severe asthma, or when the maintenance dose of inhaled steroids is reduced, and quickly reduced down to the levels in patients with stable asthma after steroid treatment. Exhaled NO has been successfully used to monitor anti-inflammatory treatment with inhaled corticosteroids in asthma. Exhaled NO is extremely sensitive and rapid marker of the dose-dependent effect of steroid treatment, or asthma deterioration, which is increased to any changes in lung function, provocative concentration causing a 20% fall in forced expiratory volume, sputum eosinophilia or asthma symptoms. Exhaled NO is not increased in stable chronic obstructive pulmonary disease (COPD), but patients with unstable COPD, or bronchiectasis have high NO levels. Exhaled and nasal NO are diag- nostically low in cystic fibrosis and primary pulmonary dyskinesia. Analysis of exhaled air, including nitric oxide, is feasible and could provide a noninvasive method for use in monitoring and management of lung diseases. Eur Respir J 2000; 16: 781-792.
To clarify the current role of balloon angioplasty in interventional cardiology, in an era of increasing development of new devices, especially stents, we performed a retrospective comparative evaluation within the well-known BENESTENT trial. We defined a balloon angioplasty result of diameter stenosis less than 30% by quantitative angiography a 'stent-like' result and compared 6-month angiographic and 1-year clinical outcome with patients undergoing Palmaz-Schatz stent implantation. Patients having a so-defined 'stent-like' result had similar angiographic and clinical outcomes to patients receiving a stent. It is concluded that achievement of a postangioplasty diameter stenosis less than 30% may be considered clinically equivalent to the average result of Palmaz-Schatz stent implantation.