No abstract is provided for this article.
Objectives The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed by a few months. Background With improved scaffold design and modified manufacturing process of its polymer, the second iteration of ABSORB (BVS 1.1) has improved performance to prevent a scaffold area reduction at 6 months. Methods Fifty-six patients were enrolled and received 57 ABSORB scaffolds. Quantitative coronary angiography, intravascular ultrasound (IVUS), analysis of radiofrequency backscattering, echogenicity and optical coherence tomography (OCT) were performed at baseline and at 12-month follow-up. Results Overall the scaffold area remained unchanged with IVUS as well as with OCT, whereas the radiofrequency backscattering and the echogenicity of the struts decreased by 16.8% (p < 0.001) and 20% (p < 0.001), respectively; more specifically, the strut core area on OCT decreased by 11.4% (p = 0.003). Despite the absence of scaffold area loss, pharmacological vasomotion was restored. On an intention-to-treat basis, the angiographic late lumen loss amounted to 0.27 ± 0.32 mm with an IVUS relative decrease in minimal lumen area of 1.94% (p = 0.12), without significant changes in mean lumen area. The OCT at follow-up showed that 96.69% of the struts were covered and that malapposition, initially observed in 18 scaffolds was only detected at follow-up in 4 scaffolds. Two patients experienced peri-procedural and iatrogenic myocardial infarction, respectively, whereas 2 underwent repeat intervention, resulting in the major adverse cardiac event rate of 7.1% (4 of 56). Conclusions The 12-month performance of the second-generation ABSORB bioresorbable everolimus-eluting scaffold justifies the conduct of a randomized trial against current best standards. (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00856856)
No abstract is provided for this article.
No abstract is provided for this article.
Data for the Royal Society Open Science article, 'Enhancing energy absorption through sequential instabilities in mechanical metamaterials' published in 2023.
COPD is a chronic inflammatory lung disease associated with an increased pro-inflammatory macrophage (mφ) response whereby cells produce increased pro-inflammatory mediators CXCL8 and TNFα and decreased anti-inflammatory mediator IL-10. A monocyte-derived macrophage (MDM) model was used to study the effect of adherence and fetal calf serum (FCS) on mφ phenotype in non-smokers (NS n=3), smokers (S n=3) and COPD patients (COPD n=3). Monocytes were isolated and cultured for 12d in either adherent or non-adherent plates in the presence or absence of FCS and addition of either GM-CSF (G-mφ, M1) or M-CSF (M-mφ, M2). MDM were stimulated for 24h with either LPS or IL-4 and levels of CXCL8, TNFα and IL-10 measured by ELISA. Baseline cytokine production was minimal and did not differ between groups. G-mφ from COPD patients stimulated with LPS produced significantly more TNFα and CXCL8 compared to NS and S (Table 1). This persisted when G-mφ were cultured without serum or adherence. Lower levels of cytokines were released by M-mφ, although COPD MDM remained pro-inflammatory. M-mφ from S and COPD patients stimulated with IL-4 released less IL-10 than cells from NS (Table 2). This effect was lost in FCS-free media. COPD MDM consistently produce more pro-inflammatory cytokines and less IL-10 regardless of culture condition. FCS may be priming MDM to produce more cytokines when stimulated ex-vivo . These data suggest that circulating monocytes are primed in patients with COPD to generate a pro-inflammatory mφ regardless of environment.