Although the safety of drug-eluting stents has been under considerable scrutiny, limited real-world follow-up data extending up to 4 years are available. The randomized clinical trials carefully selected patients and are not reflective of everyday practice. From April to October 2002, 508 consecutive patients treated with sirolimus-eluting stents (SES) were enrolled. The control group consisted of 450 patients treated with bare-metal stents during the preceding 6 months. After 4 years of follow-up, the incidence of composite major adverse clinical events (all-cause death, myocardial infarction, or target vessel revascularization) was found to be significantly lower in the SES group (23.0% vs 28.7%, adjusted hazard ratio 0.66, 95% confidence interval 0.51 to 0.86), as were rates of target vessel revascularization (12.2% vs 17.8%, adjusted hazard ratio 0.57, 95% confidence interval 0.39 to 0.83). There were no differences in all-cause mortality (10.5% for SES vs 10.6% for bare-metal stents, p = 0.9) or in the rates of cardiac death (4.5% vs 6.9%, p = 0.1). Although there was no difference in overall stent thrombosis (2.3% vs 2.2%, p = 1.0), SES had a higher rate of very late stent thrombosis (1.4% vs 0%, p = 0.02), balanced by a lower rate of early stent thrombosis (0.4% vs 1.8%, p = 0.05). In conclusion, after 4 years, SES were found to remain safe and effective compared with bare-metal stents. Nevertheless, the higher rate of very late stent thrombosis remains a concern. Longer term follow-up will be required to determine the extent of this problem.
The use of recycled glass powder (RCGP) is investigated as a partial replacement for ground granulated blast furnace slag in blended CEM II/A-LL cements using thermodynamic modelling to simulate cement paste hydration at a water-to-cement (w/c) ratio of 0.5. This study allows a rapid means of examining the likely evolution of these materials over the first two to three years, allowing experimental work to focus on promising formulations. A comparison is made between the evolving solid phase and solution chemistries of four materials: a standard Portland-limestone (CEM II/A-LL), a ‘control’ blend, comprising equal quantities of CEM II/A-LL with GGBS and two novel blended cements containing RCGP. These represent 15% replacement (by mass) of GGBS by RCGP blended with either 40% or 60% CEM II/A-LL. The simulations were performed using the code HYDCEM, a cement hydration simulator, which calls on the thermodynamic model PHREEQC to sequentially simulate the evolution of the four cements. The results suggest that partial replacement of GGBS by 15% RCGP results in no significant change in system chemistry. The partial replacement of cementitious slag by waste container glass provides a route by which this material can be diverted from the landfill inventory, and the mass-balance and energy balance implications will be reported elsewhere.
Conference Abstract| February 01 1984 New Device for Airflow Measurement: Comparison with Pneumotachograph and Differentiated Respitrace Volume S. E. Mannix; S. E. Mannix 1Department of Medicine, Royal Postgraduate Medical School, Hammersmith Hospital, London W12 OHS Search for other works by this author on: This Site PubMed Google Scholar P. Chowienczyk; P. Chowienczyk 1Department of Medicine, Royal Postgraduate Medical School, Hammersmith Hospital, London W12 OHS Search for other works by this author on: This Site PubMed Google Scholar P. J. Barnes; P. J. Barnes 1Department of Medicine, Royal Postgraduate Medical School, Hammersmith Hospital, London W12 OHS Search for other works by this author on: This Site PubMed Google Scholar N. B. Pride N. B. Pride 1Department of Medicine, Royal Postgraduate Medical School, Hammersmith Hospital, London W12 OHS Search for other works by this author on: This Site PubMed Google Scholar Clin Sci (Lond) (1984) 66 (2): 58P. https://doi.org/10.1042/cs066058Pa_pt2 Views Icon Views Article contents Figures & tables Video Audio Supplementary Data Peer Review Share Icon Share Twitter LinkedIn Cite Icon Cite Get Permissions Citation S. E. Mannix, P. Chowienczyk, P. J. Barnes, N. B. Pride; New Device for Airflow Measurement: Comparison with Pneumotachograph and Differentiated Respitrace Volume. Clin Sci (Lond) 1 February 1984; 66 (2): 58P. doi: https://doi.org/10.1042/cs066058Pa_pt2 Download citation file: Ris (Zotero) Reference Manager EasyBib Bookends Mendeley Papers EndNote RefWorks BibTex toolbar search Search Dropdown Menu toolbar search search input Search input auto suggest filter your search All ContentAll JournalsClinical Science Search Advanced Search This content is only available as a PDF. © 1984 The Biochemical Society and the Medical Research Society1984 Article PDF first page preview Close Modal You do not currently have access to this content.
No abstract is provided for this article.